The device should be set up in a location not exposed to humidity and damp.
The setting up location must be clean, dry and well-ventilated. During opera-
tion, the housing may heat up to approx. 75 °C. Therefore maintain a minimum
clear distance of 100 mm and make sure that the ventilation slots are not cov-
ered.
The space provided for the device must not be smaller than the following di-
mensions, since a minimum all round clearance of 100 mm must be maintained.
Length: 420 mm / Width: 410 mm / Height: 190 mm
The separate box for the device must be provided with ventilation holes at the
top and sides, with a total area of 10,000 mm².
The charger should be placed as close as possible to the battery, but always in
a separate box. The box for the battery must have a ventilation hole facing
towards the outside.
Attach the device securely with the four fastening screws supplied.
Important
Make sure that the ventilation slots remain unobstructed! The minimum clear
distance must be 100 mm all around! Insufficient ventilation can cause over-
heating of the device!
The device is designed for operation in ambient temperatures of up to 35 °C. If
the temperature inside the device rises due to a lack of air circulation or due to
high ambient temperature, the charging current is automatically reduced in
steps.