Method 2
Instructions for use with ozone generator placed outside the vehicle
1) connect the power supply cord of the device through the rear socket (9);
2) connect the schuko plug into the mains;
3) place the device outside the vehicle in a stable, horizontal position (e.g.: on a trolley/table or
the vehicle hood, NOT on the floor or ground);
4) connect one end of the supplied silicone hose to the ozone outlet nozzle (6);
5) slightly open the car window on the driver's side and insert the other end of the silicone hose
into the passenger compartment (make sure the hose is not squeezed along its entire length).
Bring the hose around the rearview mirror inside the passenger compartment, so that the end
of the hose can be free and the ozone supply is not prevented;
6) seal the open part of the window with paper adhesive tape and close any other open
windows or doors;
7) set the time according to the minutes required for the type of treatment to be carried out in
relation to the table (5) by turning the TIMER knob (4) clockwise. Caution/ once the timer
is set, even if the time is decreased, the timer will continue to operate on the time set at the
beginning.
8) switch the device on by turning the rear ON/OFF switch (7) to position "I"; the generator starts
producing ozone and releasing it from the nozzle (6);
9) all front panel LEDs ("POWER" (1), "OZONIZER" (2) and "AIR PUMP" (3)) are lit;
10) when the set time has elapsed, the device will automatically deactivate and disinfection is
completed;
11) the front panel LEDs ("OZONIZER" (2) and "AIR PUMP" (3)) are off while the "POWER" LED (1)
is on to indicate that the rear ON/OFF switch (7) is still in the "I" position: the device is still live;
12) deactivate the device by returning the ON/OFF switch (7) to position "0";
13) the "POWER" LED (1) is off;
14) open all the doors of the passenger compartment and ventilate for 10/15 minutes in order to
lower the concentration of ozone (O ³ ) in the passenger compartment to a safe level, allowing
it to transform into oxygen (O ² ).
15) disconnect the power supply cord from the mains.