Recommendations for an effective disinfection

Open all the glovebox lids inside the vehicle, the air vents and the rear shelf where possible, so
that ozone reaches all the interior spaces in the passenger compartment.
Method 1
Instructions for use with ozone generator placed inside the vehicle
1) connect the power supply cord of the device through the rear socket (9);
2) connect the schuko plug into the mains;
3) position the ozone generator inside the vehicle in a stable and horizontal position (possibly
in the middle of the rear seat or alternatively on the driver's side mat), taking care that
there is a free space (min. 20 cm) around the device so that ozone is released from the nozzle
(6) and at the same time that the cooling fan intakes (10)
4) set the time according to the minutes required for the type of treatment to be carried out in
relation to the table (5) by turning the TIMER knob (4) clockwise. Caution/ once the timer is
set, even if the time is decreased, the timer will continue to operate on the time set at
the beginning.
5) switch the device on by turning the rear ON/OFF switch (7) to position "I"; the generator starts
producing ozone and releasing it from the nozzle (6);
6) all front panel LEDs ("POWER" (1), "OZONIZER" (2) and "AIR PUMP" (3)) are lit;
7) close the doors and windows of the passenger compartment taking care not to squeeze the
power supply cord;
8) when the set time has elapsed, the device will automatically deactivate and disinfection is
completed;
9) the front panel LEDs ("OZONIZER" (2) and "AIR PUMP" (3)) are off while the "POWER" LED (1)
is on to indicate that the rear ON/OFF switch (7) is still in the "I" position: the device is still live;
10) open all the doors of the passenger compartment and ventilate for 10/15 minutes in order to
lower the concentration of ozone (O3) in the passenger compartment to a safe level, allowing
it to transform into oxygen (O2).
11) deactivate the device by returning the ON/OFF switch (7) to position "0";
12) the "POWER" LED (1) is off;
13) disconnect the power supply cord from the mains.