1 INFORMATION ON THIS DOCUMENT
1.1 Function
The present operating instructions provide information on installation, connection and
safe use for the following articles: CS ME-03••••.
1.2 Target audience
The operations described in these operating instructions must be carried out by quali-
fied personnel only, who are fully capable of understanding them, and with the techni-
cal qualifications required for operating the machines and plants in which the safety
devices are to be installed.
1.3 Application field
These instructions apply exclusively to the products listed in paragraph Function, and
their accessories.
1.4 Original instructions
The Italian language version is the original set of instructions for the device. Versions
provided in other languages are translations of the original instructions.

2 SYMBOLS USED

This symbol indicates any relevant additional information
Attention: Any failure to observe this warning note can cause damage or mal-
function, including possible loss of the safety function.
3 DESCRIPTION
3.1 Device description
The safety device described in this manual is defined according to the Machinery
Directive 2006/42/EC as logic component for safety functions.
The contact expansion modules to which these usage instructions apply are devices
specifically designed and manufactured for use on industrial machines. Upon opening
of at least one channel, the safety function ensures that the safety relay must open its
output contacts within the defined reaction time.
3.2 Device functions
This device is suitable for the following applications: as contact expansion mod-
ule for semiconductor outputs (light barriers of type 2 or type 4) in safety circuits up
to category 4 acc. to EN ISO 13849-1, up to SIL 3 acc. to EN 62061 and up to PL e
acc. to EN ISO 13849-1 (where the respective achievable category, SIL and PL are
dependent on the upstream safety module).
- 2 inputs for OSSDs.
- Output contacts: 3 NO safety contacts, 1 NC feedback contact/EDM.
- LED indicators for switching state of the channels 1 and 2.
- Screw terminals or plug-in terminals with screw connections or spring terminals (de-
pending on the model).
- Snap-mounting on DIN rails.
3.3 Intended use of the device
- The device described in these operating instructions is designed to be applied on
industrial machines.
- The direct sale of this device to the public is prohibited. Installation and use must be
carried out by qualified personnel only.
- The use of the device for purposes other than those specified in these operating
instructions is prohibited.
- Any use other than as expressly specified in these operating instructions shall be
considered unintended by the manufacturer.
- Also considered unintended use:
a) using the device after having made structural, technical, or electrical modifications
to it;
b) using the product in a field of application other than as described in paragraph
TEChNICAL DATA.

4 OPERATION

4.1 Operating diagram
CS ME03••••
t
A
Legend:
t
: Response time
A
t
: Release time
R1
OS1
OS2
13/14, 23/34,
33/34
EDM/EDM
t
R1
4/12
e-mail:
Pizzato Elettrica Srl
web site: www.pizzato.com
via Torino, 1
36063 MAROSTICA (VI)
Phone:
ITALY
4.2 Wiring diagrams
Semiconductor outputs (example: light barriers)
1 channel
Configuration
with
+
ESPE (PNP)
24 Vdc
EDM
OSSD
-
OS1
OS2
EDM
EDM
CS ME-03
A2
5 INTERNAL WIRING DIAGRAM
OS1
LED
CH1
K1
LED
CH2
A2
-
:
Insulated against U
imp
6 FAULTS
LED state
Possible fault
CH1
CH2
- No power supply to the
module.
- Wrong wiring.
- Power supply conductor/s cut.
- External fuse broken.
- Short circuit between chan-
nels.
- Failure in base module.
- Internal expansion module
fault.
CH1
CH2
- Internal expansion module
fault.
CH1
CH2
- Internal expansion module
fault.
Legend:
= led on;
= led off.

7 INSTRUCTIONS FOR PROPER USE

7.1 Installation
Attention: Do not exceed the tightening torque of the terminal screws specified
in the present operating instructions.
Attention: Observe the wiring of the terminals: incorrect wiring can damage the
device which may result in loss of the safety function.
- Install only inside a cabinet with protection degree not less than IP54 according to
EN 60529.
- Always affix the device with the specific DIN rail adaptor acc. to EN 60715.
- Do not stress the device with bending and torsion.
- Do not modify or open the device for any reason.
- The device carries out an operator protection function. Any inadequate installation
or tampering can cause serious injuries and even death, property damage, and eco-
nomic losses.
- These devices must not be bypassed, removed or disabled in any other way.
- If the machine where the device is installed is used for a purpose other than that
specified, the device may not provide the operator with efficient protection.
- The safety category of the system (according to EN ISO 13849-1), including the safe-
ty device, also depends on the external components connected to it and their type.
info@pizzato.com
ZE FOG52A19-EU
+39.0424.470.930
2 channels
Configuration with
+
ESPE (PNP)
24 Vdc
EDM
OSSD1
-
OS1
EDM
EDM
CS ME-03
+
13
23
33
OS2
EDM
K2
14
24
34
EDM
Recommended action
Check the wiring, the fuse and
the function of the base module.
If the fault persists, replace the
module.
Replace the module
Replace the module
OSSD2
OS2
A2

Werbung