Herunterladen Inhalt Inhalt Diese Seite drucken

Symbols Used; Operation - pizzato CS FS-1 Serie Anleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

1 INFORMATION ON THIS DOCUMENT
1.1 Function
The present operating instructions provide information on installation, connection and
safe use for the following articles: CS FS-1•••••
1.2 Target audience
The operations described in these operating instructions must be carried out by quali-
fied personnel only, who are fully capable of understanding them, and with the techni-
cal qualifications required for operating the machines and plants in which the safety
devices are to be installed.
1.3 Application field
These instructions apply exclusively to the products listed in paragraph Function, and
their accessories.
1.4 Original instructions
The Italian language version is the original set of instructions for the device. Versions
provided in other languages are translations of the original instructions.

2 SYMBOLS USED

This symbol indicates any relevant additional information
Attention: Any failure to observe this warning note can cause damage or mal-
function, including possible loss of the safety function.
3 DESCRIPTION
3.1 Device description
The safety device described in this manual is defined according to the Machinery
Directive 2006/42/EC as logic component for safety functions.
The safety modules to which these usage instructions refer are devices specifically
designed and manufactured for use on industrial machines. The safety function en-
sures that after the supply voltage is applied, the outputs are activated with a delay
(switch-on delay). The safety function is only performed after an internal integrity test
of the safety circuit and relay has been completed and if the feedback channel at Y1-
Y2 is closed. If there is no supply voltage, the module deactivates the safety outputs
within the specified release time.
3.2 Device functions
This device is suitable for the following applications: as safety timer module in
safety circuits up to category 4 and PL e acc. to EN ISO 13849-1 and SIL 3 acc. to
EN 62061.
- Timing circuits by means of safety system with self-monitoring and redundancy.
- Release command for interlocked safety devices.
- Indicator LEDs for the switching state of channels 1 and 2 (CH1, CH2) and applica-
tion of the supply voltage (PWR).
- In the event of a failure, the device switches to a safe state and deactivates the
safety output.
- Without muting input, no bridging of the safety function.
- Screw terminals or plug-in terminals with screw connections or spring terminals (de-
pending on the model).
- Snap-mounting on DIN rails.
3.3 Intended use of the device
- The device described in these operating instructions is designed to be applied on
industrial machines.
- The direct sale of this device to the public is prohibited. Installation and use must be
carried out by qualified personnel only.
- The use of the device for purposes other than those specified in these operating
instructions is prohibited.
- Any use other than as expressly specified in these operating instructions shall be
considered unintended by the manufacturer.
- Also considered unintended use:
a) using the device after having made structural, technical, or electrical modifications
to it;
b) using the product in a field of application other than as described in paragraph
TECHNICAL DATA.

4 OPERATION

4.1 Operating diagram
CS FS-1•••••
Delay on
t
A
Legend:
t
: Adjustable response time:
A
t
: Release time in absence of power supply
R
t
R
0.3 ... 3 s, 0.3 s steps
(articles CS FS-11••••)
1 ... 10 s, 1 s steps
(articles CS FS-12••••)
3 ... 30 s, 3 s steps
(articles CS FS-13••••)
30 ... 300 s, 30 s steps (articles CS FS-14••••)
Pizzato Elettrica Srl
via Torino, 1
36063 MAROSTICA (VI)
ITALY
Note: For articles CS FS-10••••-TFxx, the response time t
seconds (xx is included in the code structure).
4.2 Application example
The diagram illustrates the working principle of a typical circuit for monitoring a safety
device with guard locking in the de-energised state and manual release of the indi-
vidual doors.
L/+
F
F
K1
K2
A1
Y1
Y2
17
CS FS-1
A2
18
Door
release
button
Safety
locking
switch with
blocking of
the guard
N/-
4.3 Increase of number and load capacity of contacts
If necessary the number and the load capacity of output contacts can be increased by
using external contactors with forcibly guided contacts
L /+
K3
Y1
N /-
Feedback circuit for external contactors
5 INTERNAL WIRING DIAGRAM
A1
A2
Legend:
A1-A2:
supply
17-18:
NO safety contact
A1/A2
25-26, 35-36: NC auxiliary contacts
17/18
Y1-Y2:
Feedback contact
25/26
6 FAULTS
35/36
LED state
PWR
CH1
4/12
e-mail:
info@pizzato.com
web site: www.pizzato.com
Phone:
+39.0424.470.930
F
STOP
START
A1
S11 S12 S31
Base module
Safety
switch
A2
S21 S22 S35
A1
21
A2
22
F
Y2
17
18
K3
Y1 Y2
LED
CH1
LOGIC
LOGIC
K2
LED
PWR
K1
TIMER 1
TIMER 2
Possible fault
CH2
- No power supply to the
module.
- Wrong wiring.
- Power supply connections cut.
- External fuse broken.
- Internal module fault.
ZE FOG63A19-EU
is permanently set to xx
A
F
F
K1
K2
S33
S34
13
23
14
24
K1
K2
M
35
17
25
LED
CH2
18
26
36
Recommended action
Check the wiring and
check the fuse.
If the fault persists,
replace the module.

Werbung