DEVICE WIRING:

The ecoLINE PRO has four contact inputs and one relay output, which can be
configured in the programming software for the task at hand.
Attention! Do NOT connect the connector of the antenna directly or
indirectly to the protective ground, because this may damage the device!
Attention! Do NOT use the COM terminal for powering up the module,
because this can lead to damaging the components!
Inputs:
The NO or NC dry contacts should be connected between the selected input and
the COM terminal.
Outputs:
The OUT output provides a normally open (NO) dry relay contact as the default
state, and a closed contact when controlled. The output supports a load of
1A@24V DC.
The LINE terminals provide a simulated phone line output, which should be
connected to the (RING - TIP) phone line input of the alarm system capable for
reporting over a landline.
Attention! Do NOT connect the terminals of the device directly or indirectly
to the protective ground, because this may damage the device!
Transparent serial port:
The ecoLINE PRO has a transparent serial port, which is suitable for
bidirectional transparent data transfer over the Internet. The wiring needed for
this function differs on a case to case basis, and it highly depends on the
connected device, and the need for a logic level converter.
For more information on this process, please refer to the ecoLINE PRO
Installation and Application Manual.