G Operating Instructions
Measurement microphone
Item no. 1221088
Intended use
The measurement microphone is intended to convert acoustic signals (sound waves) into electri-
cal signals.
The low-level audio output may be connected only to the suitable microphone inputs of audio and
measurement devices.
Any use other than as described above is not permitted and can damage the product. In addition,
it can lead to hazards such as short-circuit, fire, etc.
Read the operating instructions carefully and keep them for later reference.
No part of the product may be modified or converted.
The safety instructions must be observed at all times.
This product complies with the applicable national and European requirements. All names of com-
panies and products are the trademarks of the respective owners. All rights reserved.
Package contents
• Microphone
• Microphone clip
• Operating instructions
Safety Instructions
F irst, read the complete operating instructions carefully, as they contain important
information about proper operation of the device.
D amage due to failure to follow these operating instructions will void the warranty!
We do not assume any liability for any resulting damage!
W e do not assume any liability for material and personal damage caused by improper
use or non-compliance with the safety instructions! In such cases, the warranty will
be null and void!
• For safety reasons, any unauthorised conversion and/or modification of the meas-
urement microphone is not permitted.
• Operate the measurement microphone only via a device with phantom powering (9-
52 V/DC).
• When you connect the the measurement microphone, also follow the safety instruc-
tions of the device to which it is to be connected.
• Do not expose the product to high temperatures, strong vibrations, dripping water or
water spray.
• Use the product only in a temperate and not in a tropical climate.
• This product is not a toy and should be kept out of reach of children.
• Don't leave packaging material lying around carelessly; it may become a dangerous
plaything for children.
• Handle the product with care; it can be damaged by impact, blows, or accidental
drops, even from a low height.
• Also observe any further safety instructions in the individual chapters of these oper-
ating instructions.
• In commercial institutions, the accident prevention regulations of the Employer's Li-
ability Insurance Association for Electrical Systems and Operating Facilities are to
be observed.
• If in doubt about how to connect the product correctly, or should any questions arise
that are not answered in these operating instructions, please contact our technical
service or any other professional expert.
Features
• High quality condenser microphone for measurement applications and for high-quality record-
ing of music and almost all other acoustic sources
• Ultra-linear frequency response and wide dynamic range
• Omnidirectional characteristic
• Clear and transparent sound reproduction
Getting Started
T he device to which the measurement microphone is to be connected must work with
phantom power (9-52 V/DC) to power the microphone.
T o avoid distortion or mismatching, which could damage the microphone or the con-
nected audio device, the microphone may only be connected to suitable microphone
inputs. Please refer to the connection data contained in the "Technical data" section.
T o connect the microphone, only use a suitable shielded microphone cable. Use of
other cables may lead to interference.
N ever point the microphone towards the sound exits of loudspeakers, as this may lead
to acoustical feedback that could damage the loudspeakers or the connected device.
• Mount the microphone clip onto a microphone stand.
• Insert the shaft of the microphone into the clip designed for the microphone.
• Switch off the device to which the microphone is connected.
• Connect the microphone input of your device to the XLR connector on the microphone.
• On your audio or measurement device, enable phantom power for the microphone.
• Turn your audio or measurement device on.
• Adjust the sensitivity of your audio device by using the corresponding input level control on the
microphone (see the instructions for the audio device).
Maintenance and Cleaning
This device is maintenance-free.
Please use a soft, dry or slightly damp cloth for cleaning.
Never use aggressive cleaning agents or chemical solutions; this may lead to damages to the
surface of the casing.
Disposal
Electronic devices are recyclables and must not be disposed of in the household
waste!
Please dispose of the product, when it is no longer of use, according to the current
statutory requirements.
Technical Data
Impedance ....................................................250 Ohm ± -30% (@1 kHz)
Frequency response ....................................50-20,000 Hz
Sensitivity ......................................................-63 dB +3 dB (0 dB = 1V/µbar @1 kHz)
Max. input level SPL ....................................105 dB (1 kHz @ 1% THD)
S/N ratio.........................................................>66 dB
Phantom power ............................................9-52 V/DC
Omnidirectional characteristic ..................Ball
Operation principle ......................................Electret condenser microphone
Dimensions....................................................144 x 19 mm
Weight ............................................................99 g
Operation and storage temperature: ........-20 to +60 °C / <60% rH
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent
the technical status at the time of printing.
© Copyright 2014 by Conrad Electronic SE.

Werbung

loading