Herunterladen Diese Seite drucken

VOLTCRAFT NPS-65 Bedienungsanleitung Seite 2

Usb notebook-netzteil
Vorschau ausblenden Andere Handbücher für NPS-65:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OPERATING INSTRUCTIONS
NPS-65 USB NOTEBOOK POWER SUPPLY UNIT
Item No. 51 40 01
1.
INTENDED USE
This product is designed to supply USB devices and other electric devices such as notebooks or netbooks with power,
providing six different output voltages to select from. The connected load's current consumption must not exceed the
maximum output rating of the product. Power is supplied via a standard mains socket (100 - 240 V/AC, 50/60 Hz). The
product should only be used in dry indoor areas. The product features both short-circuit and overload protection.
This product fulfils European and national requirements related to electromagnetic compatibility (EMC).
CE conformity has been verified and the relevant statements and documents have been deposited at the
manufacturer.
Unauthorised conversion and/or modification of the device are inadmissible because of safety and approval reasons
(CE). Any usage other than described above is not permitted and can damage the product and lead to associated risks
such as short-circuit, fire, electric shock, etc. Please read the operating instructions thoroughly and keep them for further
reference.
2.
CONTENT Of DELIVERY
Power supply unit
Power cord
9 x Low-voltage plugs
Operating instructions
3.
SAfETY INSTRUCTIONS
We do not assume liability for resulting damages to property or personal injury if the product
has been abused in any way or damaged by improper use or failure to observe these operating
instructions. The warranty/ guarantee will then expire!
The icon with exclamation mark indicates important information in the operating instructions.
Carefully read the whole operating instructions before operating the device, otherwise there is risk
of danger.
Persons / Product
The product is not a toy and should be kept out of reach of children!
When used in conjunction with other devices, observe the operating instructions and safety notices of connected
devices.
The product must not be subjected to heavy mechanical stress.
The product must not be exposed it to extreme temperatures, direct sunlight, intense vibration, or dampness.
Make sure to observe the polarity and magnitude of the output voltage. Incorrect polarity or excessive voltage input
leads to the destruction of the connected electrical appliance.
Sufficient ventilation is essential when operating the product. Do not cover the product. Never place the product on a
table cloth or on a carpet! Place it on a hard, flame resistant base.
The product should not be used immediately after it has been brought from an area of cold temperature to an area
of warm temperature. Condensed water might destroy the product. Wait until the product adapts to the new ambient
temperature before use.
Make sure that the output of the power adapter is not short-circuited.
If there is reason to believe that safe operation is no longer possible, put the device out of operation and secure it
against unintended operation. Safe operation is no longer possible if:
-
the product shows visible damages,
-
the product was stored under unfavourable conditions for a long period of time,
-
the product no longer works and
-
the product was subject to considerable transport stress.
Miscellaneous
Repair works must only be carried out by a specialist/ specialist workshop.
If you have queries about handling the device, that are not answered in this operating instruction, our technical support
is available under the following address and telephone number: Voltcraft
phone 0180 / 586 582 7
4.
OPERATION
Connecting an electric load
1.
Set the output voltage on the back of the power supply unit. To do this, slide the switch into the desired position using a
tool (e.g. a screwdriver or tip of a pen). Make sure the switch engages properly when set into position.
The power supply unit's output voltage must match the input voltage of the electric consumer.
2.
Select one of the nine low-voltage plugs matching the input socket and polarity of the electric consumer (see table).
3.
Connect the plug to the connector at the end of the output cable. Voltage reversal of the output plug is not possible for
security reasons. The inner contact is positive (+), the outer negative (–).
Disconnect the power supply unit from the mains socket before replacing the low-voltage plug or resetting the
output voltage.
4.
Connect the low-voltage plug to the switched-off consumer.
5.
Connect the power cord's low-voltage plug with the matching socket of the power supply unit.
6.
Connect the mains plug to a standard mains socket (100 - 240 V/AC, 50/60 Hz). The LED on the top of the power supply
unit indicates operational readiness.
7.
Put the power supply unit onto a solid, flame-retardant surface and ensure that the power supply unit is sufficiently
ventilated.
8.
9.
Connecting a USB load
1.
2.
3.
4.
5.
6.
Version 02/11
5.
When cleaning, the power adapter must be disconnected from mains socket and electrical loads. Only use dry and soft
cloth to clear the housing of the power adapter. Do not use abrasive or solvents!
6.
7.
Low-voltage plugs
, 92242 Hirschau, Lindenweg 15, Germany,
®
These operating instructions are published by Voltcraft®,
Lindenweg 15, D-92242 Hirschau/ Germany, Phone +49 180 586 582 7.
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in
electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited.
The operating instructions reflect the current technical specifications at time of print.
We reserve the right to change the technical or physical specifications.
© Copyright 2011 by Voltcraft®.
Now switch the connected consumer on. If it does not function properly, switch it off immediately and disconnect it from
the power supply unit.
Remove the power supply unit from the mains when it is no longer in use.
Connect the switched-off USB device to the power supply unit's USB port.
Connect the power cord's low-voltage plug with the matching socket of the power supply unit.
Connect the mains plug to a standard mains socket (100 - 240 V/AC, 50/60 Hz). The LED on the top of the power supply
unit indicates operational readiness.
Put the power supply unit onto a solid, flame-retardant surface and ensure that the power supply unit is sufficiently
ventilated.
Now switch the connected USB device on. If it does not function properly, switch it off immediately and disconnect it
from the power supply unit.
Remove the power supply unit from the mains when it is no longer in use.
USB devices and other electric loads can be operated in parallel. However, make sure that the power input of
the connected devices does not exceed the power supply unit's total power output.
MAINTENANCE
DISPOSAL
In order to preserve, protect and improve the quality of environment, protect human health and utilise natural
resources prudently and rationally, the user should return unserviceable product to relevant facilities in
accordance with statutory regulations.
The crossed-out wheeled bin indicates the product needs to be disposed separately and not as municipal
waste.
TECHNICAL DATA
Operating voltage:
100 - 240 V/AC, 50/60 Hz
Output voltage / current:
5 V/DC, 600 mA (USB)
9.5 / 12 V/DC, 4500 mA ±10 %
15 V/DC, 4000 mA ±10 %
18 / 19 V/DC, 3160 mA ±10 %
20 V/DC, 3000 mA ±10 %
Max. output power:
63 W
Cable length:
1.2 m (input cable)
1.5 m (output cable)
Operating temperature:
0 ºC to +35 ºC, 10 % to 85 % RH
Storage temperature:
-10 ºC to +55 ºC, 5 % to 95 % RH
Dimensions (W x H x D):
118 x 33 x 52 mm
Weight:
261 g
Imprint
Plug
Plug Ø (outer / inner)
A
5.5 / 2.1 mm
C
4.75 / 1.7 mm
D
6.3 / 3 mm
E
6.5 / 1.4 mm
G
5 / 1 mm
H
5.5 / 1.9 mm
P
5.5 / 2.5 mm
Q
7.4 / 0.6 mm
R
5.5 / 1.7 mm
Suitable for
IBM, Acer
Compaq, Asus
Toshiba
Fujitsu, Panasonic, Sony
Samsung
Acer
Acer, Compaq, Dell, Gateway, HP, Toshiba,
Winbook, IBM
Compaq
Acer Aspire One
V3_0211_02-SB

Werbung

loading

Diese Anleitung auch für:

51 40 01