P R E P E R AT I O N
Fill brake fluid into the storage tank. Connect the adapter and switch
on pressure. Vent air from the brake fluid hose (Fig. 1).
L E A K T E S T
Connect the EU adapter to the expansion tank for brake fluid and apply
pressure of 0.5 bar. Leave the system to rest for 10 minutes and then
check whether the pressure has remained constant (Fig. 2).
1.
Proceed with the brake bleeding process if the pressure has
remained constant.
2.
There is a leak if the pressure has dropped. If so, first check the
system for leaks.