Herunterladen Inhalt Inhalt Diese Seite drucken

Notes On Cleaning; Troubleshooting - Bresser Erudit MO Bedienungsanleitung

Durchlicht-mikroskop
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
8.3. Troubleshooting: the device isn't recognised by the
computer (USB)
1. This occurs in rare cases whith some OEM Windows Vista
or XP versions. The device is not defective. Updating the
notebook or PC USB driver usually suffices.
2. If not, proceed as below. (The maker cannot accept any li-
ability whatsoever in these cases
Delete ghost devices. These are devices not actually currently
connected to your computer. The reason for this is that Win-
dows generates a system settings entry for each USB device (
e.g USB Stick) on each port. It then seeks that/those device/s
each time it's started. This slows down USB device recogni-
tion and Windows booting and causes non-recognition of USB
ports.
Cleaning up the system environment and deleting devices that
are no longer in use helps here. To do so right click WORK-
PLACE (COMPUTER in Vista) and open the PROPERTIES
menu. Then click the ADVANCED tab (ADVANCED SYSTEM
SETTINGS in Vista) and then ENVIRONMENT VARIABLES.
Choose the NEW option in ENVIRONMENT VARIABLES. Enter
the following under VARIABLE NAME.
devmgr_show_nonpresent_devices
Under VARIABLE VALUE enter „1".
Confirm your input with OK and then reboot the computer.
Change to the device manager. In the VIEW menu activate the
SHOW DEVICES OPTION. The ghost devices previously not
shown will now be displayed in light grey. Check the various
categories including USB, memory size, etc. Only delete en-
tries for devices you no longer use.
Source: Microsoft Knowledge Base
1
http://support.microsoft.com/kb/315539/en
9. Using the MicrOkular
9.1. Preparation
1. Slide a specimen under your microscope and focus on it.
2. Remove the eyepiece and Barlow lens from the eyepiece
support and the dust cap from your MikrOkular and install
same in the eyepiece supports instead of the Barlow lens.
3. Start your PC if you haven't yet and connect your MikrOku-
lar to the USB port of your computer.
9.2. Showing and saving MicrOkular images on your PC
1. Start the Photomizer SE Software.
2. Click „Open camera"
3. In the event that you have connected more than one unit,
you can choose the desired unit in the subsequent selec-
tion. Click on „USB 2.0 Webcam". If only one device is con-
nected, this step is omitted.
4. The camera image should now be visible on your screen.
Focus the microscope image.
5. Click „Capture" to record an image. It will then be shown
on the right.
6. Click on it to select it and then click „Transfer image".
7. This takes you to the Photomizer SE software.
8. File - Save as
9.3. The Photomizer SE Software
If you need help in the „Photomizer SE" programme click „?"
and then „Open help". If you need further assistance please
visit the maker's home page at www.photomizer.net
Downloaded from
www.Manualslib.com
).
1
1
manuals search engine

NOTES on cleaning

Separate the device from the power supply before cleaning
(remove plug).
Only use a dry cloth to clean the exterior of the device.
NOTE!
Do not use any cleaning fluid to avoid damaging
the electronics.
Clean the lenses (eyepiece and/or lens) with a soft and lint-free
cloth only (e.g. microfibre).
NOTE!
Do not apply excess pressure to the cloth so as
to avoid scratching the lenses.
To remove more stubborn dirt, moisten the cleaning cloth with
an eyeglass-cleaning solution and wipe the lenses gently.
Protect the device from dust and moisture! After use - in par-
ticular in situations of high humidity - let the device acclimatize
for a short period of time, so that the residual moisture can
dissipate. Remove the dust cover and store it in the included
bag.

Troubleshooting

Error
No picture visible
Picture flickers
while viewing
with PC eyepiece
Software installation
reports "not XP approved"
- 13 -
Solution
• switch light on
• put condenser lens
in place
• adjust focus
• if necessary, adjust resolution
of the video graphics board
• confirm by clicking "OK"
DE
AT
CH
GB
IE
FR
CH
BE
IT
ES

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

51-10000

Inhaltsverzeichnis