HVAC
The control panel confirms the operation performed and goes back to the settings for the temperature zones.
After defining the temperature zone the HVAC menu will be displayed as illustrated in the example of Fig. 4.
• Touching
• Touching
• Touching
Clima
Zona 23
Termostato 23 Biblioteca
• Touching
Menu
mode or, for thermostats that permit fan coil control, you can set the fan speed.
3.3 Operating modes.
As mentioned in par. 3.1, it is possible to select the desired thermostat to view the read temperature and check
whether the zone is active; in addition it is possible to change the type of operation. Depending on the installed
thermostat (display with buttons or touchscreen) the operating modes are as follows:
Thermostat with buttons (art. 20513, 20514, 19513, 19514, 16953, 16954, 14513, 14514)
• OFF = off.
• TIMED OFF = off for a selectable number of hours (then it switches back on returning to the previous operation).
• ANTIFREEZE = the thermostat switches on in HEATING mode only if the ambient drops under the set antifreeze
temperature (e.g. 6°C).
• REDUCTION = manual temperature typically used at night (e.g. 18°C in winter).
• TIMED REDUCTION = as above, for a selectable number of hours (then it returns to the previous operation).
• MANUAL = is the classic operation of traditional thermostats (the desired temperature is set manually with no
time limit).
• TIMED MANUAL = as above, for a selectable number of hours (then it returns to the previous operation).
• AUTOMATIC = activates weekly programming that has previously been configured on the control panel.
• OVERRIDE = this option, which can be used when the timer-thermostat is operating on Automatic with daily or
weekly programming, is used for temporarily changing a previously set temperature value within the program.
This function is useful when, at a certain time, the desired temperature is different to the programmed one; in
particular, it is possible to define a different temperature value to the one set in the program and for a time interval
that can also be set.
Thermostat with touch screen (art. 02951)
• OFF = off.
• PROTECTION = Depending on whether in heating mode (winter) or cooling mode (summer), the thermostat
activates the Antifreeze or Too hot safeguards respectively, which prevent the risk of damaging the system.
• REDUCTION = manual temperature typically used at night (e.g. 18°C in winter).
• MANUAL = is the classic operation of traditional thermostats (the desired temperature is set manually with no
time limit).
• TIMED MANUAL = as above, for a selectable number of hours (then it returns to the previous operation).
42
Downloaded from
www.Manualslib.com
Menu displays the control panel's main menu;
Setup displays the zone parameters;
Clima
Zona 23
Termostato 23 Biblioteca
displays the thermostat operating mode;
Menu
Setup
manually forces the current temperature set point independently of the current operating
Setup