CLEANING AND MAINTENANCE
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no servicable parts inside the device except for the fuse. Maintenance and service operations are
only to be carried out by authorized dealers.
Replacing the fuse
If the fine-wire fuse of the device fuses, only replace the fuse by a fuse of same type and rating.
Please note: This fuse is being used for both 115 V and 230 V.
Before replacing the fuse, unplug mains lead.
Procedure:
Step 1: Open the fuseholder on the rearpanel with a fitting screwdriver.
Step 2: Remove the old fuse from the fuseholder.
Step 3: Install the new fuse in the fuseholder.
Step 4: Replace the fuseholder in the housing.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device becomes damaged, it has to be replaced by a special power supply
cable available at your dealer.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Power supply:
Power consumption:
Input level:
Input impedance:
Output level:
Output impedance:
Frequency range:
S/N-ratio:
Frequencies:
Control range:
Distortion:
Dimensions:
Weight:
Fuse:
Bitte beachten Sie: Technische Änderungen ohne vorherige Ankündigung und Irrtum vorbehalten.
08.01.2003 ©
Downloaded from
www.Manualslib.com
Disconnect from mains before starting maintenance operation!
115/230 V AC, 50/60 Hz ~
7 W
-10 dB (300 mV)
22,000 Ohms/stereo
-10 dB (300 mV)
600 Ohms/stereo
5 - 65,000 Hz (-1.5 dB)
100 dB
25/40/63/100/160/250/400/630Hz/1k/1,6k/2,5k/4k/6,3k/10k/16 kHz
-6 dB to +6 dB
-12 dB to +12 dB
< 0.01 %
482 x 53 x 193 mm
3.2 kg
T 0,25 A, 250 V
manuals search engine
DANGER TO LIFE!
16/22
10200036X18NXS_V_1_0.DOC