GmbH
Programming (for interface options):
Settigns:
Accuracy:
Measurements:
Accuracy:
Measuring rate:
Programming (for interface options) – Fast AD-Converter (Option ZS13):
Measurements:
Accuracy:
Measuring rate:
Other Specifications:
Potential of the
Inputs:
Parallel Operation: Master-Slave Operation of up to 3 devices, also at different
Input-off Resistance: >50k
Test-end Voltage:
Cooling:
Noise:
Mechanics:
Dimensions:
Depth:
Weight:
Elektronische Lasten Serie ZSLV
Electronic Loads Series ZSLV
16 Bit resolution
see accuracy of settings
18 Bit resolution
Current:
±0.2% of meas. value, ±0.05% of range
Voltage:
±0.1% of meas. value, ±0.05% of range
Power:
Product of current and voltage accuracy
ca. 3 measurements/s
13 Bit resolution
Current:
±0.6% of meas. value, ±0.15% of range
Voltage:
±0.3% of meas. value, ±0.15% of range
Power:
Product of current and voltage accuracy
min.: 200µs
The input terminals are isolated against the earth potential.
With the Standard Analog I/O Output it may be shifted with
max. 125 V from the earth potential.
When the Isolated Analog I/O Output (Option ZS06) is used
the max. isolation voltage is 500V against earth potential.
(besides installed Zero-Volt-Option
sizes
for battery testing an external test end voltage can be set
temperature-controlled radial fans
58dBA in 1m distance
19 (483mm), 5HU (222,25mm)
561mm
34kg