Problem
There is sparking in the
cavity.
There is sparking in the
cavity.
The turntable set makes
scratching or grinding
noise.
The appliance stop to op-
erate without a clear rea-
son.
If you cannot find a solution to the problem
yourself, contact your dealer or the customer
service centre.
We recommend that you write the data here:
Model (MOD.)
Product number (PNC)
Serial number (S.N.)

Installation

Caution! Do not block the air vents. If
you do that, the appliance can overheat.
Caution! Do not connect the appliance
to adapters or extension leads. This can
cause overloading and risk of fire.
• The appliance is for a kitchen counter top
use only. It must be placed on a stable and
flat surface.
• Put the appliance far away from steam, hot
air and water splashes.
• If you transport the appliance in cold weath-
er, do not activate it immediately after the in-
stallation. Let is stand in the room tempera-
ture and absorb the heat.
Electrical installation
Warning! Only a qualified person must
do the electrical installation.
The manufacturer is not responsible if you
do not follow the safety precautions from
the chapter "Safety Information".
20
Possible cause
There are metal dishes or dishes with
metal trim.
There are metal skewers or alumini-
um foil that touches the interior walls.
There is an object or dirt below the
glass cooking tray.
There is a malfunction.
Remove the dish from the appliance.
Make sure that the skewers and foil
does not touch the interior walls.
Clean the area below the glass
cooking tray.
If this situation repeats call the cus-
tomer service center.
The necessary data for the customer service
center is on the rating plate on the appliance.
.........................................
.........................................
.........................................
This appliance is supplied with a main cable
and main plug.
Caution! Minimum installation height is
85 cm.
C
Minimal distances
Dimension
A
B
C
Remedy
A
B
mm
100
76
76