General Safety Information
• The AC and DC power supplies are not designed to function in parallel. Do not operate the AC and DC power supplies at the same
time.
• The power cords must meet the following criteria:
• The power cord must have an electrical rating that is greater than that of the electrical current rating marked on the product.
• The power cord must have safety ground pin or contact that is suitable for the electrical outlet.
• The power supply cords are the main disconnect device to AC or DC power. The socket outlets must be near the equipment and read-
ily accessible for disconnection.
• The power supply cords must be plugged into socket-outlets that are provided with a suitable earth ground.
This equipment is designed to permit the connection of the grounded conductor of the DC supply circuit to the grounded conductor at the
equipment. If this connection is made, all of the following must be met:
• This equipment should be connected directly to the DC supply system grounding electrode conductor or to a bonding jumper from
a grounding terminal bar or bus to which the DC supply system grounding electrode conductor is connected.
• This equipment should be located in the same immediate area (such as adjacent cabinets) as any other equipment that has a con-
nection between the grounded conductor of the same DC supply circuit and the grounding conductor, and also the point of ground-
ing of the DC system. The DC system should be grounded elsewhere.
• The DC supply source is to be located within the same premises as the equipment.
• Switching or disconnecting devices should not be in the grounded circuit conductor between the DC source and the point of con-
nection of the grounding electrode conductor.
The power supply in this product contains no user-serviceable parts. Do not open the power supply. Hazardous voltage, current and energy
levels are present inside the power supply. Return to manufacturer for servicing.
When replacing a hot-plug power supply, unplug the power cord to the power supply being replaced before removing it from the server.
CAUTION
If the server has been running, any installed processor(s) and heat sink(s) may be hot. Unless you are adding or removing
a hot-plug component, allow the system to cool before opening the covers to avoid the possibility of coming into contact
with hot component(s). During a hot-plug installation, be careful when removing or installing the hot-plug component(s) since some surfaces
will be hot.
CAUTION
To avoid injury, do not contact moving fan blades. If your system is supplied with a guard over the fan, do not operate the
system without the fan guard in place.
Rack Mount Warnings
The equipment rack must be anchored to an unmovable support to prevent it from tipping when a server or piece of equipment is extended
from it. The equipment rack must be installed according to the rack manufacturer's instructions.
Install equipment in the rack from the bottom up, with the heaviest equipment at the bottom of the rack.
Extend only one piece of equipment from the rack at a time.
You are responsible for installing a main power disconnect for the entire rack unit. This main disconnect must be readily accessible, and it must
be labeled as controlling power to the entire unit, not just to the server(s).
To avoid risk of potential electric shock, a proper safety ground must be implemented for the rack and each piece of equipment installed in it.
12
Symantec SV2800 Series Safety and Regulatory Compliance Guide