Product Information

Symantec SV2800 Series Specifications

Specifications and configurations are subject to change without notice. For the most up to date information and specifications, see:
https://www.symantec.com/products
Parameter
Dimensions and Weight
Enclosure
Dimensions (L x W x H)
Weight (maximum)
Mounting Options
Operating Environment
Power Input
Input Voltage Rating
Input Current Rating
Input Frequency Rating
Output Power
Voltage
Current
Maximum Power
Maximum Thermal Rating
Temperature
Humidity
Altitude
Airflow Requirements
106
Specification
1U, Rack-mountable
728mm x 433mm x 44mm (28.70 in x 17.2in x 1.73in)
19.8kg (43.5 lb.), +/- 5%
Mounting hardware included
AC or DC power
100 to 240V~ (AC), or -40 to -72V
10A maximum over the full range per power supply (AC), or 20 / 10 amps max at any high/
low range (DC)
47- 63 Hz (AC), or 0 Hz (DC)
DC Power
12V
54A
750 Watts (505 Watts typical)
Max: 1725 BTU/Hr
10°C to 35°C (50°F to 95°F)
5% - 85% relative, non-condensing
Operating: Up to 1800M (0 - 6,000 ft.)
1.9m³/minute (70ft³/minute)
Note: Restriction of the airflow, such as blocking the front or back or enclosing the
unit in a cabinet without sufficient clearance may cause the appliance to overheat,
even if the ambient temperature is in the operating range.
Airflow in all of the units enters at the front of the chassis and exits at the rear of the
chassis. A minimum recommended clearance in the front and back is 12cm / 5". This
minimum can only be used if low temperature air can be brought to the front and
warm air can be taken from the rear.