Intended use
The pump is suitable for use e.g. in an indoor fountain, a small indoor pond or a mini water
feature.
For safety and approval purposes, you must not rebuild and/or modify this product. If you use
the product for purposes other than those described above, the product may be damaged. In
addition, improper use can result in short circuits, fires, electric shocks or other hazards. Read
the instructions carefully and store them in a safe place. Make this product available to third
parties only together with its operating instructions.
This product complies with the statutory national and European requirements. All company
names and product names are trademarks of their respective owners. All rights reserved.
Contents
• Indoor fountain pump
• Pipe adapter for hose connection (possibly already connected to the pump outlet)
• Operating instructions
Up-to-date operating instructions
Download the latest operating instructions at www.conrad.com/downloads or
scan the QR code shown. Follow the instructions on the website.
Explanation of the symbols
The lightning symbol inside a triangle is a warning to inform you of potential risks of
personal injury, such as electrical shock.
This symbol indicates specific risks associated with handling, function and use.
The "arrow" symbol indicates special tips and operating information.
The product is designed according to Protection Class II.
Observe the operating instructions!
Safety Instructions
Read the operating instructions carefully and especially observe the safety
information. If you do not follow the safety instructions and information on
proper handling in this manual, we assume no liability for any resulting per-
sonal injury or damage to property. Such cases will invalidate the warranty/
guarantee.
a) General
• For reasons of safety and certification the unauthorised alteration and/or modifica-
tion of the product is not permitted.
• The product is not a toy. Devices operated using mains voltage do not belong in
the hands of children. Therefore, be especially careful when children are around.
Use the product where it is out of the reach of children.
• The pump is designed according to Protection Class II and Protection Type IPx8.
Use only a proper power socket as source of electricity in accordance with the
specifications of the public supply network.
• At commercial institutions, the accident prevention regulations of the Employer's
Liability Insurance Association for Electrical Systems and Operating Facilities are
to be observed!
• Do not leave packaging material lying around,carelessly; it could become a dan-
gerous toy for children.
• Please handle the product carefully; jolts, impacts or a fall even from a low height
can damage the product.
• If you have any questions that are not answered in these operating instructions,
please contact our technical support centre or consult a professional. Please con-
sult a specialist if you have any doubts regarding the use or safety of the product.
b) Operation
• The socket outlet to connect the pump must be easily accessible.
• The A/C power plug must not get damp or wet. Make sure, when you position the
pump, that no water runs down the power supply cord towards the plug; the cord
must form a drip loop.
Danger of electric shock!
• These pumps are not for use in swimming pools, bathtubs or showers.
• The product may be used only indoors. It is not suited for outdoor use.
• Do not pull the power plug from the mains socket by pulling on the cable.
• Make sure that the mains cable is not pinched or damaged by sharp edges.
• If the pump or power cord is damaged, do not touch it; there is danger to life from
electric shock!
First, turn off the mains voltage to all poles of the mains socket to which the pump
is connected (e.g. switch off at the corresponding circuit breaker or remove the
safety fuse, then turn off at the ELCB).
Then you can remove the mains plug from the mains socket.
Do not use the pump any longer and dispose of it in an environmentally-friendly
manner. A damaged mains cable cannot be replaced!
• The pump is not suitable for dry runs; it will be destroyed after a short time of
running dry-loss of warranty. Operate the pump only when it is fully submerged
under water.
• Only clear water is permitted as the liquid to be pumped (temperature
+5 °C.....+35 °C). Never use other liquids (e.g. salt water, gasoline, heating oil,
chemicals, solvents or foodstuffs).
Connection and Getting Started
Please follow chapter "Safety Instructions".
Secure a suitable hose at the outlet connection, if necessary. Ensure that the hose is stable and
cannot work itself loose. Secure the hose, for example, with a cable tie.
Set the pump in the water, e.g. in an indoor fountain. The pump must be submerged completely.
Move the pump around somewhat so that the air in the pump can escape.
Make sure that the intake openings of the pump are not covered when choosing an installation
site.
Using the suction cups at the bottom, the pump can be fastened on any smooth surfaces (such
as glass, metal).
If the surface is suitable, you can also fix the pump in place by screws. For this purpose, pull
out the four legs with the suction cups; then the pump can be mounted via the holes, one each
on the right and on the left side, and suitable screws.
During operation, you may need to use a suitable underlay (e.g. around the outside
of the indoor fountain), so that any water that sprays out cannot cause any damage
to furniture or floors.
To start the pump, plug the mains plug into a mains socket.
The pump will start up immediately after connection.
If little or no water is pumped, there is still some air in the pump. Wait a few seconds, or unplug
the pump briefly and then plug it back in.
When you do this, it is imperative that you make sure that the power cord forms a
drip loop. This prevents the water from travelling along the cord toward the socket
outlet.
Failure to observe this poses a danger to life from electric shock!
To pump
Drip loop