Controller main operating modes
Heating mode
To start the appliance in this mode, use button 1.
In this mode, the convector heater shall maintain the temperature set. Message in field Operating mode - no
message. The display shows the current measured and set temperatures, the power indicator scale, the time,
and date.

Standby mode

To start the appliance in this mode, use button 1.
In this mode, when the measured temperature falls below the temperature set, the heater shall not switch on.
However, when the temperature drops below 7° C, the
Message in field Operating mode - Standby
The current measured temperature, time, and date are shown on the display.
Delayed Start mode
Message in field Operating mode - Standby
When the convector heater is in OFF mode, pressing and holding for 2 seconds on the ▲ button allows you to
enter time when the appliance shall switch on automatically. The time is set in 10 minutes steps. The delayed
start can be programmed up to 24 hours. At entry in Delayed Start mode setting, the default time is the current
time, rounded up to 10 minutes, and then pressing the ▲ or ▼ buttons you may increase or decrease the time by steps of 10 minutes. If
any of the ▲ or ▼ buttons is held for more than 0.7 seconds, the value automatically starts to increase or decrease at 4 units per
second. When the Delayed Start mode is activated, in the middle of the display is shown the turn-on time. If you want to adjust the preset
time, hold down the ▲ button again. The Delay Start mode is canceled by pressing the On / Off button. The convector heater shall then
switch to Heat mode. When the power is turned off while the Delay Start mode is on, the controller shall store the delay time. If the set
time shall occur before the power is restored, then the controller shall remain in OFF state when the power is restored.
Antifrost mode
This function shall switch on the convector heater automatically and independently of the selected mode when the room temperature
drops below 7°C. For this purpose, the convector heater must be plugged into the mains and the
be in the "I" position. When activating this mode, a minimum room temperature of 7°C shall be maintained.
Message in field Operating mode - Antifrost
When the room temperature raises above 7°C, the Anti-freeze safety mode switches off.
Sleep mode
In this mode the convector heater shall, within 2 hours, automatically and gradually decrease with 3 degrees the temperature set. This
mode activates by pressing and holding button 2 for more than 2 seconds when the convector is in Heat mode. When this mode is
activated for five seconds in the display middle field is shown Sleep Mode On, then the display takes the appearance of Heat mode.
Message in field Operating mode - Sleep.
The sleep mode is interrupted by pressing button 1 when the convector heater is switched off. The Sleep mode will turn itself off after 6
hours!
Timers mode / Program mode
The controller has a built-in weekly programmer that allows you to create seven independently set operating time intervals, and each
interval can be repeated over the days of the week. The weekly programmer can operate in two modes - Timer and Program. Switching
from one mode to the other is possible by changing the Timers setting in the sub-menu System When the setting is On/Off, the
controller is in the Timers mode, with only start and end of the time intervals and the days of the week for which it is valid.
Message in field Operating mode - Timers
When the setting of Timers in System is Change t, the controller is in the Program mode, where, in addition to the start and end of the
time intervals and days of the week for which the program applies, a temperature may be entered.
Message in field Operating mode - Program
Each program or timer set can be activated / deactivated. When introducing a start and an end it must be borne in mind that the
controller does not allow the end time to be before the start one.
With a weekly programmer set, hold the OK button for more than 2 seconds and all timers set shall be deactivated by displaying the
Timer Stop message for 5 seconds, then the convector shall switch to Heat mode without a weekly programmer.
Antifrost mode
mode is activated.
convector heater on / off switch
EN
must

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis