Instructions for the installation of induction loops
The induction loops must be installed at least 15 cm from fixed
metal objects and at least 1 m from moving metal objects. The
maximum distance to the road surface should be 5 cm.
Keep loop cables away from mains power cables.
Use a normal single-pole 1.5 mm² diameter cable. If the cable is
buried directly, it must have a suitable insulation. If hot casting
compound is used ensure for temperature resistance of the cable.
Preferably, induction loops are made square or rectangular. If it is
not possible to use pre-fabricated loops, the installation is per-
formed as shown in the figure below, in a groove cut into the road
surface. In this case, the loop cable must be firmly fixed in the
groove and then the groove must be filled with the potting com-
pound. The corners should be at an angle of 45° to avoid damage
to the insulation of the cable.
8 mm
For installation of the loop cable use the number of turns indicated
in the table.
Induction loop perimeter
less than 3 m
from 3 to 4 m
from 4 to 6 m
from 6 to 12 m
over 12 m
The two cable ends from the loop to the detector must be twisted at
least 20 times per meter.
Do not make any joints on the cable. If this is still necessary, the
contact points must be protected against the ingress of moisture by
means of cast resin.
VEK M1H_DE_GB_FR_NL_IT_ES_CE_FAAC_1.docx
30-50 mm
Number of turns
6
5
4
3
2