Digi-Pas
®
DIGIPAS
USER MANUAL
Clip-On (Module)
DIGITAL LEVEL
DWL-130 (0.05° Resolution)
Product of Singapore
Battery Compartment
Push down the battery cover to slide open.
connect the battery
Digi-Pas
®
DIGIPAS
Eine Abteilung der
Unternehmensgruppe
BEDIENUNGSANLEITUNG
Modul zum Anklemmen
DIGITALE WASSERWAAGE
DWL 130 (Auflösung 0,05°)
Produkt aus Singapur
Batteriefach
Batteriefach leicht drücken, um die Klappe
herauszuschieben.
Vor dem ersten Gebrauch den Schutzstreifen entfernen,
um die Batterie zu aktivieren.
Device Overview :
Locking Flip
LCD Display
device
Alt.Zero :
- Set any angle to 0° as reference
MODE SELECT :
- Press to change display unit
: °(Degree), %slope, mm/M, In/Ft
- Press & Hold to freeze Display value
Calibration Instruction
1.
Clip the device to a spirit level, make sure the device is
securely cliped on the level, turn on the device then press
'CAL' button once the screen will display flashing "CAL1".
2. a
Place the device on a flat and clean surface, press
"MODE" button once, the screen will display countdown,
wait until screen countdown reach "0" and show "CAL2".
b
Rotate the device (180°) parallel to the surface then press
"MODE" button again, the screen will display countdown,
wait until screen countdown reach "0" and show "CAL3".
c
Position the device vertically (-90°) on a level surface,
press "MODE" button again, the screen will display
countdown, wait until screen countdown reach "0" and
show "CAL4".
d
Rotate the device 180° parallel vertically to the surface
(+90°) then press "MODE" button again, the screen will
display countdown, wait until screen countdown reach "0".
3.
Calibration Done.
Note: Ensure the device is kept still during calibration
Caution
Digi-Pas device is calibrated in the factory for maximum accuracy.
®
User can re-calibrate when necessary.
Refer to www.digipas.com for video demonstration on how to
calibrate the device.
Geräteübersicht :
Feststellklappe
LCD Display
ON/OFF : Gerät an-
oder ausschalten
Alt.Zero :
- Beliebigen Winkel auf 0° stellen
- Gedrückt halten, um Summton an- ode auszuschalten
MODE SELECT :
- Kurz drücken, um das
Anzeigeformat zu ändern: Grad,
Prozent, mm/m, in/ft
- Länger gedrückt halten, um den auf dem Display angezeigten Wert zu halten
Anleitung zur Kalibrierung
1.
Bringen Sie das Gerät auf einer Wasserwaage an. Stellen
Sie dabei sicher, dass dieses fest auf der Wasserwaage
aufsitzt. Schalten Sie das Gerät dann Einmal CAL
drücken, auf dem Display blinkt „CAL1" auf.
2. a
Platzieren Sie das Gerät auf einer flachen und sauberen
Oberfläche, drücken Sie dann einmal den MODE-Knopf.
Auf dem Display wird ein Countdown erscheinen. Warten
Sie, bis dieser bei „0" angelangt ist und „CAL2" anzeigt.
b
Drehen Sie das Gerät (180°) parallel zur Oberfläche und
drücken Sie wieder den MODE-Knopf. Auf dem Display
wird ein Countdown erscheinen. Warten Sie, bis dieser
bei „0" angelangt ist und „CAL3" anzeigt.
c
Platzieren Sie das Gerät vertikal (-90°) an einer ebenen
Fläche und drücken Sie wieder den MODE-Knopf. Auf
dem Display wird ein Countdown erscheinen.Warten Sie,
bis dieser bei „0" angelangt ist und „CAL4" anzeigt.
d
Rotate the device 180° parallel vertically to the Drehen
Sie das Gerät (180°) parallel vertikal zur Oberfläche
(+90°) und drücken Sie wieder den MODE-Knopf. Auf
dem Display wird ein Countdown erscheinen. Warten Sie,
bis dieser bei „0" angelangt ist.
3.
Kalibrierung abgeschlossen.
HINWEIS:
Stellen Sie sicher, dass das Gerät während der
Kalibrierung stillsteht.
ACHTUNG
Geräte von Digi-Pas werden in der Fabrik auf die maximale
®
Genauigkeit kalibriert. Der Benutzer kann bei Bedarf nachkalibrieren.
Eine Videoanleitung zur Kalibrierung des Geräts finden Sie auf
unserer Website www.digipas.de.
Adjustable Clip
Buzzer sound
CAL: Activate Calibration Mode
Calibration Illustration
Verstellbarer Clip
Summton
CAL: Kalibriermodus aktivieren
Kalibrierung
SCHRITT 1
z.B. Tischfläche
Einmal CAL drücken
SCHRITT 2
Einmal MODE drücken
Einmal MODE
drücken
Technical Specification
Dimension
: 95 x 48 x 22mm
Weight
: 110 Grams
Operating Temp
: 0° ~ +50°(Celcius)
Storage Temp
: -10° ~ +60°(Celcius)
Battery
: 2 x CR2032 (3V)
Cleaning
• Keep the level dry and clean. Remove
any moisture or dirt with a soft, dry cloth.
• Do not use harsh chemicals, strong
detergents or cleaning solvents to clean
the level.
• Do not submerge device in water while
cleaning .Wiping or cleaning on device
surface is sufficient
Warranty
Digi-Pas® Digital level is warranted to the original purchaser to be free
from defects in workmanship and material. JSB Tech will, at its option,
repair or replace any detective part which may malfunction under
normal and proper use within a warranty period of 1 (one) year from
the date of shipment. This one year warranty clause is NOT applicable
to European Union (EU) member states. Purchases made in EU
member states will be covered by the existing consumer laws across
the European Union, which provide statutory warranty rights in
addition to the coverage of one year warranty period. The foregoing
warranty shall not apply to defects resulting from misuse, abuse or
transfer by the Buyer, Buyer-supplied software or interfacing,
unauthorized modification or operation outside of environmental
specifications for the product. JSB Tech does not warrant that the
operation of the instrument software, or firmware, will be uninterrupted
or error free.
The exclusive remedy under any and all warrants and guarantees,
expressed herein, and we shall not be liable for damages from loss or
delay of equipments uses, consequential, or incidental damage. No
other warranty is expressed or implied. JSB Tech specifically disclaims
the implied warranties of merchantability and fitness for a particular
purpose.
Distributed by :
Manufactured by
JSB TECH Pte Ltd
Email: info@digipas.com
www.digipas.com
JIM-2-00082-99-002
Technische Spezifikationen
Größe
: 95 x 48 x 22
Gewicht
: 110 Grams
Betriebstemperatur
: 0° ~ +50°C
Aufbewahrungstemperatur
: -10° ~ +60°C
Batterie
: 2 x CR2032 (3V)
Cleaning
• Halten Sie die Wasserwaage trocken
und sauber. Entfernen Sie Feuchtigkeit
oder Schmutz mit einem weichen,
trockenen Tuch.
• Verwenden Sie zur Reinigung der
Wasserwaage keine Chemikalien,
Reinigungsmittel oder Lösungsmittel.
• Gerät nicht in Wasser eintauchen.
Äußeres Abwischen oder Reinigen ist
ausreichend.
Garantie
Für Digi-Pas® Digitale Wasserwaagen gilt eine Herstellergarantie von 1
(einem) Jahr, beginnend mit dem Versanddatum. Der Hersteller JSB
Tech garantiert, dass das Produkt frei von Materialfehlern und
Verarbeitungsfehlern an den Erstkäufer verkauft wird. Wurde das
Produkt in einem Mitgliedsstaat der Europäischen Union gekauft, gilt
vorrangig die Gewährleistung (Mängelhaftung). Die gesetzliche
Gewährleistung wird durch die Herstellergarantie in keiner Weise
eingeschränkt. Die Herstellergarantie gilt nicht bei Defekten, die durch
falschen
Gebrauch,
falsche
Handhabung
oder
unsachgemäße
Verwendung
verursacht
wurden,
sowie
durch
Fremdsoftware,
Anschluss an ungeeignete Schnittstellen oder Anschlüsse, durch
unberechtigte Modifikationen oder bei Gebrauch des Geräts außerhalb
der angegebenen empfohlenen Betriebsspezifikationen. JSB Tech
garantiert nicht den unterbrechungsfreien oder fehlerfreien Betrieb der
Gerätesoftware oder der Firmware. Die Herstellergarantie umfasst
lediglich die Nachbesserung einzelner oder aller Teile des gekauften
Geräts und weder Hersteller noch Händler sind nicht verantwortlich für
Verlust oder störungsbedingte Wartezeit von verwendeten Geräten,
sowie für versehentlich oder beabsichtigt verursachte Schäden. Es
werden keine weiteren Garantien ausgesprochen oder angedeutet. JSB
Tech garantiert nicht die Gebrauchstauglichkeit und Eignung für einen
spezifischen Verwendungszweck.
Vertrieb durch:
Hergestellt von
JSB TECH Pte Ltd
Email: info@digipas.de
www.digipas.de
JIM-2-00082-99-002