Connection:
The products are only to be installed using the following supply rating:
AC 230 V (<AC 254 V), single phase, 50/60Hz
Wire designation
Phase
Neutral
Earth
Note!
The integrated temperature sensor is directly connected to the thermostat. The connection between
sensor and thermostat should never be mechanically interrupted. This leads to loss of function and
safety also in terms of explosion protection (ATEX).

Initial Operation

Before initial or starting operation, check the equipment which is to be used and connected to be
accordant to the design data and ambient data again. This has to be carried out immediately after
installation of heating system and control device ahead of starting initial operation. The information
listed in topics "General Safety Instructions" and "Additional Safety Instructions" has to be followed.
The requisite inspections according to the standards listed under "General Safety Instructions" and
"Additional Safety Instructions" are to be documented after the installation of the electrical heating
apparatus or equipment is completed. Checking has to be recorded. Before initial operation and
setting the installation alive, the equipment has to be secured in position, completely closed (if
applicable) and fasteners tightened (if applicable).

Hazardous Areas

Hazardous areas are classified by a temperature class which indicates the highest admissible
temperature, otherwise gases or other potential explosive media can explode. The correct
temperature setting allowed in the application area does not belong to the responsibility of the
manufacturer! It is the responsibility of the operator to guarantee the correct settings of the
controller before start-up!

Maintenance and Safety

Maintenance and Safety is performed according to the standards listed under "General Safety
Instructions" and "Additional Safety Instructions", the regulations of the employer's liability
insurance associations applicable to the respective way of use, as well as other relevant rules
applying to the application. At least once per year the function of the temperature controlling device
has to be checked and the products have to be inspected for visible damage.
1235-OMH FIDR-FIBDR-FIGB-SR R16-0
= brown
= blue
= green-yellow
7 |
P a g e - S e i t e