Spannschulter-Messgerät /
Cam Angle Gauge
HSK 25 - HSK 100
6.

Adjustment

6.1.

Gauge setting

27. 1. Clean Tapers and Face
28. 2. Move handle to the right stop (Position „0")
29. 3. Set Gauge in the master taper for calibration
30. 4. Press gauge on to the face of the tool taper. The taper is spring-loaded, so
some pressure must be applied.
31. 5. Move handle to the left stop (Position „I") and set indicator to the deviation of
the certificate supplied with the gauge
6.2.

Tool taper check

32. 1. Clean Tapers and Face
33. 2. Move handle to the right stop (Position „0")
34. 3. Press gauge on to the face of the tool taper. The taper is spring-loaded, so
some pressure must be applied.
35. 4. Move handle to the left stop (Position „I") and read the scale value
Spannschulter-Messgerät_D+E
Legend:
Copyright © Diebold 2012-12 Ersteller: kh
HSK-tool shaft or
Master sleeve
Handle
Stop Screw for indicator
Indicator
Seite 11 von 14