Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

56
CAN BUS
(MS-VERSION ONLY)
1 CAN Baud Rate = 1Mbaud
2 No CAN termination inside of the battery
3 CAN Com only ON with Input on 0X300
4 CAN Speed and CAN IDs are configurable (see 5.6.12.)
5.8
ECU2BMS14V (ID = 0X300 / CALIBRATE) (FREQ. = 20MS [50HZ])
BITS
SIZE
GAIN
RANGE
[0]
1
1
[0-1]
[1]
1
1
[0-1]
[2]
1
1
[0-1]
[3]
1
1
[0-1]
[4]
1
1
[0-1]
L I T E W E R K S G M B H
|
+ 4 9 ( 0 ) 7 5 3 1 / 9 4 5 2 5 2 5
5 | E I N S A T Z D E R B A T T E R I E
DESCRIPTION
Charge override
BT On
BT Off
Disable Crash
Reset Killswitch
|
I N F O @ L I T E B L O X . D E
5 | E I N S A T Z D E R B A T T E R I E
BMS14V2ECU (ID = 0X301 / CALIBRATE) (FREQ. = 20MS [50HZ])
BITS
SIZE
GAIN
ENGINEERING RANGE
[0-11]
12
0.001
[0–4.095] V
[12-23] 12
0.001
[0–4.095] V
[24-35] 12
0.001
[0–4.095] V
[36-47] 12
0.001
[0–4.095] V
[48-63] 16
0.001
[0–65.535] V
BMS14V2ECU (ID = 0X302 / CALIBRATE) (FREQ. = 20MS [50HZ])
BITS
SIZE
GAIN
ENGINEERING RANGE
[0-3]
4
-
-
[4]
1
1
[0-1]
[5]
1
1
[0-1]
[6]
1
1
[0-1]
[7-14]
8
0.5
[0-100] %
[15-30] 16
0.1
[-3276.7–3276.8] A
[31-38] 8
10
[0–2550] A
[39-46] 8
10
[0–2550] A
[47-54] 8
1
L I T E W E R K S G M B H
|
+ 4 9 ( 0 ) 7 5 3 1 / 9 4 5 2 5 2 5
DESCRIPTION
Voltage cell 1
Voltage cell 2
Voltage cell 3
Voltage cell 4
Voltage Pack 14V
DESCRIPTION
Alive Counter
Warnlevel 1
Warnlevel 2
Warnlevel 3
SOC
Current Pack 14V
Max Current Charge
Min Current
Discharge
|
I N F O @ L I T E B L O X . D E
57

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis