It is recommended to secure the winch handle with a chain to avoid manipulations by
unauthorized people.
4.10.- Down:
Descending the load is done the other way round. Turn the winch handle (W)
counterclockwise (N2) to lower the load and retract the individual profiles until the
tower is completely folded down to its minimal height.
SEE FIGURE 10.
Just like when lifting the load, the tower may be stopped in any desired intermediate
position.
If the tower should become blocked by the emergency brake during the up or down
movement, extend the tower to its maximum height to unlock it and continue the
operation, moving the winch handle in a slow and steady way.
4.11.- For transport it is necessary to fold down the tower completely. Fix the cart with
the brake (O). Dismount the legs by releasing the retention triggers and place them in
their transporting position (S). Press the fixing screws (J).
SEE FIGURE 11.
It is very important to activate the brake (O) when the lifting tower is going to be
transported to avoid slipping of the profiles.
5. Maintenance
5.1.- All cables must be checked regularly. Faulty cables need to be replaced
immediately. Do not use the lifting tower with faulty cables. It is dangerous.
Use only torsion-free steel cables according to DIN 3060 standard.
5.2.- The tower is delivered ex works completely greased. Depending on its mechanical
strain, however, it is recommended to grease the crown wheel of the winch, the pads
and bushings of the drive shaft, the thread of the handle and the profiles of the tower
periodically.
ATTENTION:
Do not apply oil or grease to the brake mechanism.
The brake discs have been pregreased with a special heat and pressure resistant
grease. To avoid malfunctions of the winch brake, no other products must be used
except the original provided by the company.
It is not necessary to grease the brake discs.
5.3.- The lifting tower T-116 must be inspected at least once a year by a specialized
technician.
5.4.- Only original spare parts must be used to ensure a consistent operational safety.
The user shall lose all warranty claims if he uses any other than original spare parts or