Herunterladen Diese Seite drucken

Red Sea ReefLED 50 Handbuch Seite 18

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Red Sea ReefLED
Rebooting a ReefLED
In some cases, such as when the ReefLED disconnects from the ReefBeat
Cloud, it will be necessary to restart the device. This can be done in 2
ways.
Click the Reboot button from the device manager:
Device Line menu > Reboot
Alternately, you can disconnect and reconnect the power by the DC jack
and wait for the ReefLED to reboot.
Clear ReefLED settings
To permanently remove all user settings from the memory of the
ReefLED and return it to its initial default state, perform the following
steps.
If the ReefLED is connected to ReefBeat the factory reset can be
activated from the App:
Device Manager > Device Line menu > Hard Reset
If the ReefLED is not connected to ReefBeat perform the following steps:
Permanently remove (Delete) the specific ReefLED from ReefBeat.
Press the Settings button for about 15 seconds (until the indicator LED
shows a double blink), release the button and wait for about 5 seconds
until a second double blink of the indicator LED appears.
Disconnect and reconnect the power by the DC jack and wait for the
ReefLED to restart.
The unit will restart without any user settings and with the Wi-Fi
switched off, exactly as shipped from the factory. The unit will retain the
latest installed version of the firmware.
18
Device Manager >
.
Overtemperature protection
The ReefLED is designed with active cooling to ensure the longevity of the
LED array.
Fan speed will vary according to the light intensity. At very low intensity
levels such as with moonlight the fan is not required. At full LED intensity
and with an ambient temperature of about 25°C/ 77°F the fan will run at
about 85% capacity. In high ambient temperature environments, the fan
speed will increase to 100% to maintain the correct working temperature
for the LED array.
If the ambient temperature is too high or airflow to the unit is restricted
the unit will automatically dim the intensity of the LEDs or shut it down
completely to prevent damage to the unit. In the event of shutdown due
to overtemperature you will need to disconnect and reconnect the power
by the DC jack to restart. Check the unit and surroundings for the cause of
the overtemperature situation.
.
Notifications
When the ReefLED has a permanent connection to the internet, a
notification will be sent to your SMD whenever connection to the unit is
lost.
A "No communication" message could be due to a power or internet
outage, router failure or a fault with a specific connected device.
If you have more than one Red Sea connected device and connection
to one or more (but not all) devices are lost, you will receive a "Partial
communication" message. You will then be able to see the current status
of all devices from the Device Manager.
You can set how you wish to receive some of the messages from
"Notifications" in the homepage main menu.