Specifications
Input
Input
Input resistance
Rated frequency
Input capacitance
Overload capacity
Output
Output
Load
Overload range
Test signal
(internal SW monitoring)
Residual ripple
P 42000 D2 TRMS-0001-KTA :
0 ... 110 V AC (upper range value 12 ... 110 V AC)
P 42000 D2 TRMS-0002-KTA :
0 ... 500 V AC (upper range value 111.1 ... 500 V AC)
≥490 kΩ (TRMS-0001-KTA); ≥1.9 MΩ (TRMS-0002-KTA)
45 ... 65 Hz
< 100 pF
20 % full scale
P 42000 D2 TRMS-0001-KTA Peak voltage ≤ 350 V
P 42000 D2 TRMS-0002-KTA Peak voltage ≤ 1600 V
0 ... 20 mA, 4 ... 20 mA, calibrated switching;
linear transmission 0 ... 22 mA
≤ 15.4 V (700 Ω at 22 mA)
0 or > 22 mA (max. 42 mA)
> 22 mA ... 30 mA (typ. 25.5 mA)
< 10 mV
(500 Ω load)
rms