Herunterladen Inhalt Inhalt Diese Seite drucken

Activating/Deactivating The Pump Control - HomeMatic HmIP-FAL24-C6 Installations- Und Bedienungsanleitung

Fußbodenheizungsaktor – 6-fach, 24 v
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

The channel will be switched on or off for 15 minutes.
Afterwards, normal operation will be continued for the
heating zone.
8.2

Activating/deactivating the pump control

If you want to use connection terminal (H) for controlling
a heating pump, the heating zone can be switched to
pump control directly via the device. To do this, proceed
as follows:
Press the select button (B) until the LED of chan-
nel 1 starts flashing green (see fig. 7).
If the LED of channel 1 starts flashing slowly, the
pump control is activated. If the LED of channel 1
starts flashing quickly, the pump control is deac-
tivated.
If you do not want to change any parameters, you
can exit the menu by pressing the select button
(B) briefly.
To switch the parameter from activated to de-
activated or from deactivated to activated, press
and hold down the select button (B) for at least
4 seconds.
Manual operation
69

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

143237