Herunterladen Inhalt Inhalt Diese Seite drucken

Sharp PN-V701 Installationsanleitung Seite 8

Vorschau ausblenden Andere Handbücher für PN-V701:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33
Connections
Multiple monitor connection
The monitors can be aligned and used as a large screen.
[Example]
Remote control sensor box
(Supplied with the PN-ZR02 (optional))
Second monitor
Secondary
(Expansion unit)
ID No.: 2
Third monitor
Secondary
(Expansion unit)
ID No.: 3
* Always install the remote control sensor box on the primary
monitor.
nConnection with video cable
Up to 25 monitors* can be connected in a daisy chain.
*: Up to 4 monitors when the video signal is encrypted by
HDCP.
Up to 4 monitors when the first monitor's input mode is
D-SUB[COMPONENT].
Up to 2 monitors when the first monitor's input mode is
DisplayPort (MST).
First monitor
DisplayPort
output terminal
DisplayPort
input
terminal
To DisplayPort output terminal
6
E
First monitor
Primary
(Main unit)
ID No.: 1
Fourth monitor
Secondary
(Expansion unit)
ID No.: 4
Second monitor
DisplayPort
input
terminal
DisplayPort cable that supports 4K
(commercially available)
shows the signal
flow
nConnection with RS-232 cable
If you connect the monitor in a daisy chain using RS-232
cables, settings are copied from the primary (main unit) to the
secondary (expansion unit) and operation from the primary
can perform operation for all monitors.
Connect the RS-232 cables in order, starting with the first
monitor (primary monitor).
If monitors are connected in a different order they may not be
operable.
First monitor: primary
RS-232C
RS-232C
output
input
terminal
terminal
RS-232 straight cable
(commercially available)
Connect in the same way to the third and subsequent
monitors.
Up to 25 monitors can be connected. (Depending on the
length of the cable used and the surrounding environment.)
Setting each ID No. in the monitor is required.
Perform operation with the rear side buttons on the primary
monitor. To automatically assign ID numbers in order from the
primary, set AUTO ASSIGN ID No. to ON in ID SETTING on
the SETUP menu.
Second monitor: secondary
RS-232C
output terminal
Third monitor: connects to
secondary RS-232C input terminal

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis