Mounting and Operating Instructions
Contactless reader, s.m.
Item no. 26480.10
Mounting Information
Between contactless readers must be a minimum distance
of 1 m in all directions.
In outside area we recommend to use the including installation
socket.
Do not install the reader directly on metal as this would
considerably reduce the reading distance. If, however, installation
on a metal surface cannot be avoided, the adapter base item-no.
022196 (see accessories) must be used to achieve the full reading
distance.
Avoid direct sun rays.
The reader should not be exposed to plastic decomposing solvent
vapours.
Connection
Conductor
colouring
red
black
yellow
red-blue
grey
white
pink
brown
green
blue
grey-pink
violet
** RS485EN may only be used, if the reader is connected to an
ACS-8 via a potential isolation module (see connection
diagrams of ACS-8 and potential isolation module). In all other
cases this cable must not be connected. The guarantee expires
with wrong wiring, as the device might be damaged or destroyed.
P30702-45-002-02
2017-06-28
026480.10
+12V DC
GND
n.c.
n.c.
clock
data
LED red
LED yellow
LED green
D
D*
RS485EN**
D
DIP-switches
Address
DIP-switch
5
4
3
2
1
0
0
0
0
1
0
0
0
1
0
0
0
0
1
1
0
0
1
0
0
0
0
1
0
1
0
0
1
1
0
1
1
1
0
0
0
1
0
0
0
1
1
0
0
0
1
1
1
1
1
0 0 0
0
0
Terminating resistors
Terminating
DIP-switch
10
9
resistors
0
0
not placed
0
1
0
1
1
1
placed
Meaning of the LEDs
Connection diagrams can be found in the documentations of the
corresponding AC controllers.
LED meaning with AC applications:
yellow
green
red
LED
Basic
colour
condition
yellow
on
yellow
off
green
on
red
on
green
red
red
Additionally, the key and LED functions of the macro control of IQ
MultiAccess are valid (see separate manual "Supplementary functions
of IQ MultiAccess", P32205-46-0G0-xx).
GB
Baud rate
Address
DIP-switch
6
0
1
2
1
3
4
5
Reader mode
6
DIP-switch
7
8
7
8
0
0
9
0
1
0
1
1
1
31
In clock/data mode only
32
DIP-switch 7 must be set to
ON (position "1"). All the
remaining Dip-switches
must be in position "0" (OFF).
-
-
After reading
Meaning
a card
Operation / ready to read
Device is idle
PIN-Code or door code entry is
active
(only possible with readers with
RS-485 interface)
Permanently released
Permanently blocked
on
Door release
on
ID card not authorized
blinking
Read error
Subject to change