Warning! Protection against swapped poles will not be available. If the poles are swapped there
is a risk of damaging the charger and the battery/on-board vehicle power supply or a connected
consumer. It is imperative that you make sure the polarity is correct when you connect up.
Observe the maximum power consumption (see "Technical data") of the consumer.
Note:
• The direct voltage which is provided (shown in the display) is load-dependent and without load
it is approx. 14.5 V.
• This function can be used for consumers which are operated from a vehicle's cigarette lighter.
• Refer to and observe the operating manual for your 12 V consumer.
4.4 Charging the battery
1. Connect the charger to a socket.
2. Then connect the red charging cable to the positive pole of the battery.
3. Connect the black charging cable to the negative pole of the battery. You can now change the
charging settings.
4. After the battery is fully charged, pull the plug out of the socket.
5. First disconnect the black charging cable from the bodywork.
6. Then release the red charging cable from the positive pole on the battery.
Important
• Charging may create dangerous explosive gas and therefore you should avoid spark forma-
tion and naked flames whilst the battery is charging. There is a risk of explosion! It is essential
that you ventilate the rooms well.
• When "FUL " appears in the LCD display (and all increments Fig. 2/Item K), charging has been
completed. The charger holds the battery at 95% – 100% available battery capacity using
pulsed charging. If the charger shows this after just a few minutes, this indicates that the
battery capacity is low. The battery needs replacing.
• In case of positive earthing, first disconnect the red charging cable from the bodywork and
then the black charging cable from the battery.
• Screw or push the battery stoppers back into position (if there are any).
• If the mains plug is pulled out but the charger cables are still connected to the battery, the
charger will draw off a small amount of electricity from the battery. We therefore recommend
that you always completely remove the charger from the battery when not in use.
4.5 Calculating the charging time (Fig. 3)
The charging time depends on the charge status of the battery. If the battery is fully discharged,
the approximate charging time up to approx. 80% charged can be calculated using the following
formula:
Charging time/h =
20AH
60AH
90AH
150AH
The charging current should be 1/10 to 1/6 of the battery capacity.
Battery capacity in Ah
Amp. (charging current)
80%
4Hrs
10Hrs
15Hrs
25Hrs
EN-4