6. CARE AND MAINTENANCE

• Hold the machine securely at all times.
• Always keep one finger on the on/off button to be able to turn it off quickly.
For long duration operation, you can push the lock-on button (5) once.
The on/off button (3) must be pressed for this. The machine will stay on until the on/off
button is pushed quickly once again.
Setting the rotation speed
By pressing the on/off button (3), you can set the rotation speed during idle operation.
The optimal rotation speed depends on the material drilled, the operation mode, and the
inserted drill.
Light pressure on the on/off button: low rotation speed
Greater pressure on the on/off button: higher rotation speed
Selecting the rotation direction
• Do not set the left/right rotation switch during drilling.
• The rotation direction is always according to the switch position.
• Switch position R: right-rotation/forward/clockwise.To drill and to screw in screws,
push the right/left rotation switch (2) all the way to the right.
• Switch position L: left-rotation/backward/counter-clockwise. To loosen or pull out
screws and nuts, push the right/left rotation switch (2) to the left until the stopper.
Cooling the motor If the motor has intensely overheated, allow it to run idle for 2 to 3
minutes on maximum rotation speed.
CARE AND MAINTENANCE
WARNING: Always ensure that the tool is switched off and unplugged before attempting
to perform inspection or maintenance.
BRUSH REPLACEMENT When the carbon brushes are worn out, brushes must be
replaced simultaneously with genuine brushes at STATUS service centre for warranty
and post-warranty service.
GENERAL INSPECTION Regularly inspect all fasteners and ensure they are properly
tightened. Should any of the screws be loose, retighten it immediately to avoid hazards.
If the replacement of the supply cord is necessary, this has to be done by the manufac-
turer or his agent in order to avoid a safety hazard.
CLEANING For safe operation always keep the machine and its ventilation slots clean.
Regularly check to see if any dust or foreign matter has entered the ventilation slots and
the grills around the switches. Use a soft brush and/or air jet to remove any accumulated
dust. Wear safety glasses to protect your eyes whilst cleaning. Exterior plastic parts may
be cleaned with a damp cloth and mild detergent if necessary.
WARNING: Never use alcohol, petrol or other cleaning agent. Never use caustic agents
to clean plastic parts.
WARNING: Water must never come into contact with the tool.
IMPORTANT! To assure product safety and reliability, repairs, maintenance and adjust-
ment (including brush inspection and replacement) should be performed by certified
service centres or other qualified service organisations, always using genuine replace-
ment parts.
EN
8

7. TECHNICAL DATA

8. CE DECLARATION OF CONFORMITY
ATTENTION!
The consumer can independently replace only the drill chuck on this product.
TECHNICAL DATA
Model
Operating power
Capacity
Idle rotation speed n
O
Chuck capacity
Weight
Maximum drilling depth:
Wood
Steel
Concrete
Noise and vibration information
Noise emission (measured values determined according to EN 60745):
A-weighted sound pressure level
A-weighted sound power level
Wear hearing protection!
Vibration emission
Total vibration values (vector sum in the three axes)
determined according to EN 60745
Vibration emission value
CE DECLARATION OF CONFORMITY
We STATUS ITALIA S.R.L. as the responsible manufacturer declare that the
following STATUS machine(s): Impact Drill Model No./ Type: DP700 are of series
production and сonforms to the following European Directives:
Directive 2006/42/EC, Directive 2011/65/EU, EMC Directive 2014/30/EU.
And are manufactured in accordance with the following standards or standardised
documents:
EN 60745-1:2009/A11:2010, EN 60745-2-1:2010, EN 55014-1:2006,
EN 55014-2:1997/A2:2008, EN 61000-3-2:2014, EN 61000-3-3:2013.
The technical documentation kept by the manufacturer: STATUS ITALIA S.R.L.,
via Aldo Moro, 14/A, 36060 - Pianezze (VI), ITALY
220-240V~50 Hz
0-2800/min
L
94 dB(A) Uncertainty К
pA
pA
L
105 dB(A) Uncertainty К
wA
wA
a
9 m/s² Uncertainty K1.5 m/s²
ID
h
Caron Giacinto
Director
STATUS ITALIA S.R.L.
9
DP700
710W
13 mm
2 kg
25 mm
13 mm
13 mm
3.0 dB
3.0 dB
EN