14. Technical data

14.1.

Ambient conditions

The recommendations listed below should be complied with as closely as
possible, since they ensure consistent performance by the device coupled
with the minimum requirement for maintenance.
14.2.

Operation

Temperature: +10 °C to +40°
Duty cycle: 10% (S3); 1 min ON, 9 min OFF
Environment: for use only in dry indoor areas
item
92 0001
92 0003
92 0011
92 0013
92 0021
92 0023
*load evenly distributed
Mechanical and electrical data for each lift column.
max. load
max. lifting force
max. lateral load
max. lifting speed
Drive
Downloaded from
www.Manualslib.com
www.hoffmann-group.com
manuals search engine
max. load*
Height adjustment
[kg]
range
[mm]
250
750 – 1000
250
750 – 1000
250
700 – 1000
250
700 – 1000
250
700 – 1000
250
700 – 1000
per column 1600 N.
longitudinally:
1200 Nm static
500 Nm dynamic
transversely:
450 Nm static
255 Nm dynamic
9 mm/s at 24 V unloaded.
Internally mounted DC drive,
integral limit switches and 2
Hall sensors.