OTHER MALFUNCTIONS
• The Sunshower does not start properly with a UV session
If the UV lamps are still warm from an UV (or IR) session, they cannot be
immediately restarted. It is therefore important that the Sunshower fully
completes the cooling period following a session, also after an IR session. If that
does not happen, do wait for 15 minutes before starting another UV session.
• The Sunshower drops out during a UV session
The gas-discharge lamps are sensitive to dips in the mains voltage (longer than
10 ms). This may cause the Sunshower to drop out during a UV session. If this
happens, press the Stop button and allow the UV lamps to cool. The session can
be resumed when the cooling period is over.
DISPOSE OF THE SUNSHOWER
Electrical and electronic products cannot be disposed of with the normal
household waste. Dispose of the unusable product according to the valid legal
regulations.
CONCLUSION
Enjoy the positive effects of well-dosed sunlight and direct infrared heat.
Sunshower wishes you many hours of pleasure with this product. Should you
have any suggestions or complaints, please do not hesitate to contact us.
Send us an email at info@sunshower.nl or +31 (0)20 46 21 460.

TECHNICAL SPECIFICATIONS

Volt/Frequency
Power
Dimensions (whd)
Temperature range
Humidity range
Installation height
Net weight
UV class
Insulation class
UV lamp power
Lamp type
Certification
USER MANUAL DELUXE | P1072 REV F
230 V~ / 50Hz
2600 W
320 x 1870 x 160 mm
10°C - 40°C
20% - 100%
Max. 2000 m above sea level
35 kg
Type 3
I
400 W
4x UV Philips HPA Cleo Swift 250-500
5x IR 500 W
8