Herunterladen Inhalt Inhalt Diese Seite drucken

Gas Connection - Plastimo 3000 RANGE Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
An air gap of 40 mm must be allowed at the
rear of each cooker and a back stop is fitted to
ensure that this gap is maintained. (FIG 3)
Where cookers are to be fitted into a recess or built in to a unit an air gap of 20 mm must be
kept at each side (FIG 4). Use a non-combustable material for the surround such as 0.5
mm sheet steel.
Ensure that no obstruction to the units air flow is permitted at the base, sides or back.
Obstruction of the air flow can cause inefficient combustion in the oven.
UNIT DIMENSIONS (FIG 5)
Measurements
Height (mm)
Neptune
575
Pacific
440
Neptune Hob
220
Gulf
100
Caribbean
420
There should be no obstruction above the
hob burners for a minimum height of 400
mm. (FIG 4)
Width (mm)
Depth (mm)
500
420
500
420
500
420
500
380
500
420

GAS CONNECTION

These appliances are strictly for use on liquid petroleum gases at the following pressures to
the inlet
28 mbar (11.2 in w.g.) for Butane (G30)
37 mbar (14.8 in w.g.) for Propane (G31)
The gas inlet is located at the rear, top left hand side of the appliance. The gas inlet
connection fitting to the appliance should be in accordance with installation requirements
according to destination country and gas type as given in EN30-1 table A6. It is
recommended that the connecting pipe is, where possible, copper, also that an isolating cock
valve is installed in the supply pipe to the unit. For units requiring a flexible pipe a suitable
armoured pipe should be used.
Care should be taken during installation to prevent the supply pipe from being held against
the back panel of the body.
The unit is fitted with a pressure test point, located next to the connection inlet. To check the
supply pressure, remove the screw and fit a pressure gauge.
Once installed the gas connection should be tested for any gas leakage. DO ensure the area is
well ventilated and DO NOT test for a long period; if there is a leak, a build up of gases may
occur.
BURNER ADJUSTMENT AND RATES
All burners are supplied ready for use on BUTANE (G30 @ 28 mbar) / PROPANE (G31 @
37 mbar). No adjustment of the burners is required.
Heat Input (model depending) :
See table 1.