Connect water entry and drain water (if available) lines.
Protect your equipment from heat sources such as heaters, ovens, furnaces, radiator. If that is not
possible place the equipment at least 50cm away of the above stated heat sources.
Do not expose the equipment to direct sunlight due to the risk of spoilage of food due to inadequate
cooling.
Cooling unit of the equipment should definitely be in a place where it can easily intake air (where airflow
will not be obstructed).

5. ELECTRIC CONNECTION

Equipment should be feed with 220-230V 50-60Hz line voltage.
Cable section shall be chosen for supporting maximum current.
Voltage tolerance shall not exceed ± 10 %.
Equipment must be grounded. Manufacturing company assumes no responsibility in case of using the
equipment without grounding.
Sudden plugging / unplugging the equipment or power blackouts may damage the system of your
equipment due to the pressure of the refrigerant gas may not be balanced yet. Certain attention should
be paid for such incidents and it shall be known that failures caused due to such incidents are not
covered by the warranty.

6. USAGE

The equipment has been designed for professional use and should be used only by those who are trained in this
matter.

6.1. Before Starting

Check whether any damage has been caused during the montage.
Ensure that the control panel, electric wires and its connections are made properly and are damage free.
Under no circumstances supply electric to the equipment through adaptor, more than one plugs and
attachment connections.
Make sure that the ventilation holes at the front of the cooling unit of the equipment are not closed.
Wait for at least one hour before the initial startup of the equipment. This will allow the oil that have
flowed into the system during the transportation and moving to return to the compressor.
The equipment has been designed for operating in conditions of maximum 43C0 external environment
temperature (maximum 32C0 for products using static cooling system) and 60% relative humidity.
In case the above stated conditions are not met, significant losses on the operating performance of the
equipment will occur, excessive energy loss will be caused and compressor will outwear earlier.
7.