Diastolic: 40-199mmHg
d
Pulse rate: 40-180 beats/minute
Accuracy:
a
Pressure: ±3mmHg
b
Pulse rate: ±5%
Environmental temperature for
operation: 10°C~40°C(50°F~104°F)
Environmental humidity for
operation: ≤85%RH
Environmental temperature for storage
and transport: -20°C~50°C(-4°F~122°F)
Environmental humidity for storage
and transport: ≤85%RH
Environmental pressure: 80kPa-105kPa
Battery life: Approx 200 times.
All components belonging to the pressure
measuring system, including accessories:
Pump,Valve, LCD, Cuff, Sensor
Read all of the information in the
operation guide and any other literature
in the box before operating the unit.
Stay still, calm and rest for 5 minutes
before blood pressure measurement.
The cuff should be placed at the
same level as your heart.
During measurement, neither speak
nor move your body and arm.
Measuring on left wrist for
each measurement.
Please always relax at least 1 or 1.5 minutes
between measurements to allow the
blood circulation in your arm to recover.
Prolonged over-inflation (cuff pressure
exceed 300 mmHg or maintained above15
mmHg for longer than 3 minutes) of the
bladder may cause ecchymoma of your arm.
7
Consult your physician if you have
any doubt about below cases:
a
The application of the cuff over a
wound or inflammation diseases;
b
The application of the cuff on any limb
where intravascular access or therapy, or
an arterio-venous (A-V) shunt, is present;
c
The application of the cuff on the
arm on the side of a mastectomy;
d
Simultaneously used with other monitor-
ing medical equipments on the same limb;
e
Need to check the blood
circulation of the user.
8
report_p This Electronic Sphygmomanometer
is designed for adults and should never
be used on infants or young children.
Consult your physician or other health care
professionals before use on older children.
9
Do not use this unit in a moving vehicle; this
may result in erroneous measurement.
10
Blood pressure measurements determined
by this monitor are equivalent to those
obtained by a trained observer using the
cuff/stethoscope auscultation method,
within the limits prescribed by the American
National Standard Institute, Electronic
or automated sphygmomanometers.
11
Information regarding potential electro-
magnetic or other interference between
the blood pressure monitor and other
devices together with advice regarding
avoidance of such interference please see
part ELECTROMAGNETIC COMPATIBILITY
INFORMATION.It is suggested that the blood
pressure monitor be kept 10 meters away
from other wireless devices, such as WLAN
unit, cell phone, microwave oven, etc.