Chapter 2: Before You Begin
New in this release
One hardware model is added to the Avaya Ethernet Routing Switch 4500 Series in Release
5.3.
The new hardware model is Avaya Ethernet Routing Switch 4524GT-PWR.
Before you begin
Ensure the area where you install and use the 4500 Series switch meets the following
environmental requirements:
• Ambient temperature between 32° and 106° F (0° and 50° C)
• Relative humidity between 10% and 90% noncondensing
• No nearby heat sources such as hot air vents or direct sunlight
• No nearby sources of severe electromagnetic noise
• No excessive dust
• Adequate power source within six feet; one 15-Amp circuit required for each power supply
• At least 2 inches (5.08 cm) on each side of the switch unit for ventilation
• Adequate space at the front and rear of the switch for access to cables
If you are installing a single Avaya Ethernet Routing Switch on a table or shelf, ensure the
surface can support at least 15 to 20 pounds (7 to 9 kilograms).
Installing the switch on a table or shelf
You can install a single Avaya Ethernet Routing Switch on any flat surface that can safely
support the weight of the switch and attached cables (15 to 20 pounds or 7 to 9 kilograms).
The following figures provide instructions for installing the switch on a table or shelf.