The icemaker works but it
doesn't produce ice/or is melting
in the storage
The producing ice is
unformed/bad shape
The icemaker is working for long
hour/s
TROUBLE SHOOTINGS
Check
might
position and prevent ice to fall in
the storage by keeping it in the
Water storage (behind flags). Light
sliding conveyor slightly to up step
of water storage.
Check the drain, maybe the water
comes back to storage and melts
the ice. If so, you must install
icemaker higker from drain.
Last Unscrew back over, on left you
will find a blach pipe. Squeeze it so
any obstacle will remove.
You must clean the distributor and
sprayers. (See TIPS in this manual)
Check for possible rubbish in filter
of electro valve or pump.
Check pump.
Check electro valve.
Lift the front cover of device and
with the brush clean with UP and
DOWN
condenser (The component it is
first to your disposal).
Check the working temperature of
icemaker. If it is over 42 Celsius,
you have to decrease the ambient
working
icemaker somewhere else.
If nothing of above changes the
problem Please call for assistance
for authorized personnel, because
the icemaker has lost its
refrigerant. FREON (R404A) due to
transportation, hit, or from long use.