6

MAINTENANCE AND CLEANING

Pay attention to very high or very low temperature or humidity values.
The detector shall be powered continuously so as to guarantee top safety.
As regards the device's routine and extraordinary maintenance and decommissioning, it is
recommended that you should contact qualified technicians.
Check the correct operation of the device regularly, by means of the special button available or by
using test gas.
OTHER TEST METHODS MAY CAUSE DAMAGE TO THE DEVICE.
To clean the device, use a soft cloth – never use detergents or thinners!
WARNING! In case of alarm:
1. Immediately ventilate the room or enclosed space, by causing air to flow through.
2. Immediately switch off all combustion devices (e.g. burners, boilers, heaters, etc.).
3. Try to identify and remove the cause that gave rise to the alarm.
4. If the cause cannot be identified, leave the room or enclosed space and contact a qualified
technician or expert.

TECHNICAL FEATURES

Device type 'A'.
Case made of insulating, shock-proof material.
Degree of protection: IP42.
Operation ambient temperature / humidity: –10 to
40°C, relative humidity: 90% (max.).
Power supply: 230 VAC, 50 Hz.
The crossed out wheeled dust bin symbol indicates that products must be collected and disposed of separately
from household waste. Integrated batteries and accumulators can be disposed of with the product. They will be
The black bar indicates that the product was placed on the market after August 13, 2005.
By participating in separate collection of products and batteries, you will help to assure the proper disposal of
products and batteries and thus help to prevent potential negative consequences for the environment and
For more detailed information about the collection and recycling programmes available in your country, please
contact your local city offi ce or the shop where you purchased the product.
FOLLOWING INFORMATION IS ONLY FOR EU-MEMBER STATES
separated at the recycling centres.
Power consumption: 4 VA.
Sealed relay, to avoid sparks when switching.
Contact capacity: 6(2)A 250 VAC.
Electrochemical cell sensor for gas detection.
Internal light and sound alarms.
Compliant to the EN 50291 Standard.