INSTALLATION

DANGER!
­– installation must only be carried out by certified technicians. Incorrect installation could cause the
unit to run badly, with a consequent deterioration in performance.
­– the unit must be installed according to national or local standards in force at the time of installation.
Always use personal protective equipment.
­– the unit must remain accessible for maintenance, the casing must always be detachable for service
purposes
for wall or ceiling installation, the casing must always be detachable for service purposes.
The unit has sharp edges; use gloves during installation!
IMPORTANT!
Incorrect positioning or installation of the unit may amplify noise levels and vibrations generated
during operation.
ACOUSTIC ISOLATION
Insulation against airborne noise
Sound is reflected by hard materials. Soft, porous substances are best suited to absorbing airborne
sound.
Contact sound insulation
Sound travels very easily in hard materials. Contact sound insulation will largely depend on this:
­– quality of placement.
­– contactpoints. make sure that sound- and/or mechanical vibrations cannot be transferred between
different elements, e.g. between the built-in heaters and a metal carrier, through pipes, along air
ducts etc.
­– hollow acoustic spaces. where air can travel, so can sound. Isolate the built-in heaters in hollow
acoustic spaces. Avoid cavities between insulation and pipes. These form small resonance boxes.
Avoid cavities along air ducts (the acoustic effect cannot be predicted for this).