IB Series P1 Type Operating Manual

7 . St o r a g e

7.1 Storage location

Store the unit in a clean, dry place indoors.
Avoid storage outdoors or in places with humidity, dust, sudden temperature change, or corro-
sive gas.
7.2 Storage period
Storage period should be less than 1 year.
7.3 Use after storage
Oil seals will deteriorate when exposed to high temperatures and UV rays. Inspect the oil seals
before operation.
Replace the oil seals after long-term storage if there is any sign of deterioration.
After starting the reducer, verify that there is no abnormal sound, vibration, or heat rise. If supplied
as a brakemotor, check that the brake operates properly. If any anomaly is observed, contact our
nearest agent, distributor, or sales office.

8 . I n s ta l l a t i o n

Do not use the reducer for purpose other than those shown on the rating plate or in the manu-
facturing specification; otherwise, electric shock, injury, or damage to the equipment may result.
Do not place any object that will hinder ventilation around the reducer; otherwise, the cooling
effect is reduced, possibly leading to fire or burns due to excessive heat built-up.
Do not step on or hang from the reducer; otherwise, injury may result.
Do not touch the shaft end of the reducer, inside keyways, or the edge of the motor cooling fan
with bare hands; otherwise, injury may result.
When the unit is used in food processing applications vulnerable to oil contamination, install an
oil pan or other such device to cope with oil leakage due to failure or limited service life; other-
wise, oil leakage may damage products.

8.1 Place of installation

Ambient temperature:
For other ambient temperatures please consult Sumitomo Drive Technologies.
Ambient humidity:
Altitude:
Ambient atmosphere:
Location of installation: Indoors, with minimum dust and no water splashing.
Units made to special specifications are necessary for installation under conditions other than
the above.
Install the units where inspection, maintenance, and other such operations can be carried out
easily.
Install the unit on a sufficiently rigid base.
Page 12
0 - 40°C
90% max. No condensation
1000m max.
There should be no corrosive gas, explosive gas, or steam.
The place should be well ventilated without dust.
Issue: 011/2007