Herunterladen Diese Seite drucken

HANSGROHE Decor 31171223 Gebrauchsanleitung, Montageanleitung Seite 2

Vorschau ausblenden Andere Handbücher für Decor 31171223:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Safety Notes
Gloves should be worn during installation to prevent crushing and cutting
injuries.
The product may only be used for bathing, hygienic and body cleaning
purposes.
Children may only use the product unsupervised if they have been suitable
instructed and trained to use the product safely and to understand the risks of
improper operation.
The hot and cold supplies must be of equal pressures.
Only the battery housing with battery CR-P2 or power pack HG No.
30589310 supplied by Hansgrohe may be connected to the electrical
connection cable of the fittings.
A damaged connecting line must not be replaced. The transformer may no
longer be used.
The transformer and its mains plug may only be installed or plugged in in dry
interior rooms outside of the protected zones.
The transformer must not be installed in protection zones 0 or 1.
The wall socket must be outside of the protected zones. (see page 6 Fig. 5)
The fitting may be installed in protected zone 2.
Installation Instructions
• Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• The plumbing codes applicable in the respective countries must be observed.
• Leave enough space above the tap for servicing. (min. 200 mm)
• If the instantaneous water heater causes problems or if you wish to increase the
water flow, the EcoSmart
®
(flow limiter) located behind the aerator can be
removed.
• The fittings must not be installed on washstands with raised edge. (see page 6)
• At the start of operation, or after maintenance, function of the faucet may be
delayed due to reflections during adjustment of the operating distance. The
faucet will automatically calibrate itself. The self-calibration will start after
10-15 minutes.
• During initial start-up and after servicing, air in the fittings can cause an
unattractive jet pattern. The jet pattern is okay again after switching the jet on
and off about 15 times.

Electrical installation
Electrician
 The installation and test work must be performed by an authorized electrician
under consideration of DIN VDE 0100 part 701 / IEC 60364-7-701.
Electrical connection
 Voltage supply: 230 V AC ± 10 %/ 50- 60 Hz
 The circuit must be protected via a ground fault protector (RCD / FI) with a
measured differential current of ≤ 30 mA. The proper function of this protective
device must be checked at regular intervals.
 Any work may only be carried out in a de-energized state. Here, the voltage
supply must be safely separated via the main switch or mains plugs.
 The wall socket must be outside of the protected zones. (see page 60 Fig. 5)
Adjustment
This mixer has the following feature: background fade-out with integrated range
adjustment, that means the mixer is automatically adjusted on to the local
conditions (washbasin, brightness, reflection) by the sensory mechanism.
Battery operation
The indicator LED signals that the battery must be changed.
Battery voltage ≤ approx. 5.5 V: The indicator LED in the sensor window blinks
when the fitting is operated, water withdrawal continues to be possible
Battery voltage ≤ approx. 5.3 V: The indicator LED in the sensor window blinks
when the fitting is operated, water withdrawal continues to be possible
Attention! After insertion of the battery, the fitting should not be activated for
approx. 30 seconds. This time is required for self-adjustment.
Replacement, installation and disposal of batteries is subject to the regulations
specified in EN 60335-1 Appendix 3 Section 7.12.
Power supply pack operation
For the replacement of a power supply pack, the procedure corresponds to the
replacement of a battery.
2
English
Normal operation
The range of the detection area or the removal of the switch-on/off point from the
fittings depends on the ambient optical conditions (for example, the shape and
reflection of the washstand and the ambient light) as well as on the shape, the size,
the speed and the reflection of the object that was brought into the detection area.
The detection area of the fittings or the distance of the switch-on/off point from the
fittings is approx. 160 to 200 mm in normal operation.
The detection of dark (for example grey-black) objects by the fittings is inadequate
because of their low reflection. The range of the detection area or the distance of
the switch-on/off point can be smaller than 160 mm. The detection of bright or
reflecting objects by the fittings is very good as a result of their high reflectivity. The
range of the detection area or the distance of the switch-on/off point can be
greater than 200 mm. Strong light sources should not shine directly on the sensor
window of the fittings. Drops of water or condensed water on the sensor window
of the fittings can initiate unintended running of the water.
Range setting for infrared proximity electronics
It may be necessary to reduce the range of the infrared proximity electronics by
manual mode switching when the fittings are connected to very small or highly
reflecting washstands. The following two modes can be selected:
• "Maximum range" (factory setting)
• "Reduced range" (maximum range reduced by approx. 50 mm)
The LED behind the sensor window signals which mode the fittings are currently in:
• Short blinking when the fittings are closed = "reduced range"
• No blinking when the fittings are closed = "maximum range"
Perform the following steps to change from "maximum" to "reduced" range or vice
versa:
• Interrupt voltage supply of the fittings for approx. 10 s (disconnect electrical
plug connection between fittings and battery housing or power pack and
reconnect after 10 s)
• The LED blinks to indicate the software version (e.g. blinking once = software
version 1)
• When the LED lights permanently (-> calibration of infrared proximity electron-
ics), cover sensor window completely with your hand or a white piece of paper
• Remove your hand or the paper after 20 s to 40 s
• The LED indicates the currently activated mode by blinking: Once = "maximum
range", twice = "reduced range"
• The LED then lights permanently until the calibration of the just set range of the
infrared proximity switch has completed
• When the LED goes off again, the fittings are ready for operation
Technical Data
This mixer series-produced with EcoSmart
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Maximum flowing-out temperature at 50 K temperature difference and 0,3 MPa
flow pressure:
Follow-up time:
Automatic switching-off:
battery:
transformer:
Protection category:
installation site of type plate:
The product is exclusively designed for drinking water!
Symbol description
Do not use silicone containing acetic acid!
Dimensions (see page 8)
Flow diagram (see page 8)
with EcoSmart
without EcoSmart
Spare parts (see page 12)
Cleaning washbasin (see page 10)
After setting the parameters for the hygiene rinse or making a net reset, wait for
approx. 90 s before you can enable the "Clean wash basin" function.
Cleaning (see page 11)
Never use high pressure cleaners or steam cleaners to clean the fittings.
®
(flow limiter)
(1 MPa = 10 bar = 147 PSI)
230 V AC ± 10 % / 50 – 60 Hz / 20 mA
®
®
max. 0,8 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 60°C
approx. 42°C
1 - 2 s
after 10 s
CR-P2 / 6 V Lithium
IPX5
see page 12

Werbung

loading

Diese Anleitung auch für:

Decor 31173223Decor 31172223Decor 31174223