3. Set-up operations
3.1 Initial cabinet set-up
Do not power the control unit until all motors have been connected.
Connect all movement bar motors to the control unit according to the chosen cabinet confi guration.
After connecting all the motors to the control unit according to instructions, manually bring the doors to their closed positions.
3.2 Control unit power supply
00:00:10
3.3 Track memorization cycle
If this operation is not successful due to a lack of power or physical obstacles in the path of the door, simply unplug the power supply,
bring the doors to their closed positions and repeat the operation.
Wait at least 10 seconds after powering on the unit to allow it to learn and select the program to use with
the connected system.
00:00:03
After checking the correct connection of the motors to
the control unit and bringing the doors to their closed
positions, the control unit can fi nally be powered via
the power supply unit.
Activate the function for automatic detection of door
track limits, as described in Section 2.3, by long pressing
(3 seconds) the 'SET/RESET' button on the control unit.
One door at a time, starting from the fi rst door to the left
of the cabinet, the doors will move slowly towards their
respective track limit stops.
The operation may take up to a few minutes until all door
tracks have been memorized.
During this set-up phase, the movement of the
doors must not be impeded in any way.
If the positions of the track limit stops are changed,
the track memorization cycle must be repeated.
During this set-up phase, the remote control
pairing function cannot be activated.