Herunterladen Inhalt Inhalt Diese Seite drucken

Before Installation - Hafele 400.50.038 Bedienungsanleitung

Für slido flat 60 fb
Inhaltsverzeichnis

Werbung

1.6 Remote control buttons
To guarantee the compatibility of the remote control with all cabinet configurations, every remote control has 4 buttons. The active control
buttons for each configuration are indicated in the respective installation and use instructions.
1.7 Door movement program
Each door can be moved individually. If the door meets an obstacle while moving, it will automatically stop. If a door is stopped with a
force contrary to its direction of movement, it stops and starts moving in the opposite direction.
1.8 Simultaneous movement of various doors
In certain cases, various doors may be move simultaneously in the same direction. If one of the doors is stopped by an obstacle, the other
doors will automatically stop moving in order to avoid the risk of crushing or injury.
1.9 Closure of all doors
If the system is in a state with one or more doors partially or completely open, all the doors may be brought to their closed positions by
long pressing (3 seconds) any of the buttons on the remote control (see Section 1.6).
1.10 Power failure
1.11 Control unit switch
The control unit is equipped with a NO switch that closes its contact every time a door is commanded to open.
The switch can handle voltages of between 0 and 48 V and a maximum current of 2A.

2. Before installation

2.1 Prerequisites
The installation of electrical systems must be performed by specialized personnel.
• The cabinet must be installed stably and perfectly level. Any deformity or instability in the cabinet may pose a risk to user
safety and system operation.
• Check the correct functioning of the sliding system to be combined with the system and the correct positioning of track limit
stops.
• Each movement bar is equipped with a 4-metre cable for connection to control unit. The control unit power supply cable
has a length of approximately 3 metres including the power adapter. A 110-240V, 50-60Hz, AC power outlet must
therefore be accessible near to where the cabinet is installed.
• The installed electrical system must comply with applicable regulations regarding active and passive electrical protection.
2.2 Electrical connection
Make sure that the power outlet is easily accessible after installing the cabinet and system.
All connections must comply with the regulations of energy supply companies.
60
In the event of a power failure, the doors may also be moved manually, though more force will
be required due to the friction and resistance of the electromechanical system.
If power failure occurs during the movement of a door, the system will stop. When powered
again, the door will move slowly to its closed position before the system becomes fully
operational again.