1. Wiring diagram
A. For power supply: 230V 50Hz
Distribution Box(Customer prepare)
Power Supply
230V 50Hz
Earthing
B. For power supply: 400V 50Hz
Distribution Box(Customer prepare)
Power Supply
400V 50Hz
Earthing
Note:
Must be hard wired, no plug allowed.
 For your safe use in winter, it's strongly recommended to equip heating priority function.
 For the detailed wiring diagram, please refer to Appendix 1.
2.Options for protecting devices and cable specification
MODEL
Rated Current A
Breaker
Action Current mA
Fuse
A
Power Cord(mm
Signal cable(mm
NOTE: The above data is adapted to power cord ≤ 10m. If power cord is
increased. The signal cable can be extended to 50m at most.
Fuse
Breaker
Fuse
Breaker
7300714
12.0
Rated Residual
30
12.0
2
3×2.5
2
3 x 0,5
Swimming Pool Heat Pump Wiring Board
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Cord
7300715
7300772
7300716
14.5
16.5
18.0
30
30
30
14.5
16.5
18.0
3×2.5
3×2.5
3×4
3 x 0,5
3 x 0,5
3 x 0,5
- 13 -

For installers and professionals

7500717
7500718
21.0
9.0
30
30
21.0
9.0
3×4
5×2.5
3 x 0,5
3 x 0,5
10m, wire diameter must be
7500719
12.0
30
12.0
5×2.5
3 x 0,5