1. Wiring diagram
A. For power supply: 230V 50Hz
Distribution Box(Customer prepare)
Power Supply
230V 50Hz
Earthing
B. For power supply: 400V 50Hz
Distribution Box(Customer prepare)
Power Supply
400V 50Hz
Earthing
Note:
Must be hard wired, no plug allowed.
For your safe use in winter, it's strongly recommended to equip heating priority function.
For the detailed wiring diagram, please refer to Appendix 1.
2.Options for protecting devices and cable specification
MODEL
Rated Current A
Breaker
Action Current mA
Fuse
A
Power Cord(mm
Signal cable(mm
NOTE: The above data is adapted to power cord ≤ 10m. If power cord is
increased. The signal cable can be extended to 50m at most.
Fuse
Breaker
Fuse
Breaker
7300714
12.0
Rated Residual
30
12.0
2
3×2.5
)
2
3 x 0,5
)
Swimming Pool Heat Pump Wiring Board
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Cord
7300715
7300772
7300716
14.5
16.5
18.0
30
30
30
14.5
16.5
18.0
3×2.5
3×2.5
3×4
3 x 0,5
3 x 0,5
3 x 0,5
- 13 -
For installers and professionals
7500717
7500718
21.0
9.0
30
30
21.0
9.0
3×4
5×2.5
3 x 0,5
3 x 0,5
10m, wire diameter must be
>
7500719
12.0
30
12.0
5×2.5
3 x 0,5