TS EN 60669-2-1
3
TS EN 60598-2-1
Complies with ROHS Regulation Directive 2002/95/EC
10551 - 10651
CEILING ARMATURE WITH 360° MOTION
SENSOR AND EMERGENCY LIGHTING
USAGE AREAS
• At the building entrances, stair vestibules.
• At the long halls within the flats.
• At the places required within the flats.
• At the parking garage.
• At the requisite locations within the hotels.
• At the schools, hospitals and oil filing station.
"OFFERS EXTRA ENERGY SAVING FEATURE''
GENERAL SECURITY CAUTIONS
• Take off the original package and control if there is any damage of transportation and general view
of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply any liquid.
• Protect from any stroke.
• Using ~230-240V voltage is so dangerous that only the specialist electricians must install and apply.
CAUTIONS FOR INSTALLATION AND USAGE
• Installing must be carried out professionally in accordance with applicable national wiring and
electrical operating conditions.
• Turn of the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Use 2A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 10 - 15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting of the time and
daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that you
can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the glass, take of carefully and clean with a dry rag.
• Avoid mounting the detector close to objects that can cause rapid temperature changes such as
heaters, fans, refrigerators and ovents etc, and prevent the detector from point-blank sunshine.
• It can cause the device operate inaccurately if there is tree, brushes etc. in the coverage area.
• The product has Y type connection.
• The product functions can be affected by the wind in the open area conditions.

SPECIFICATIONS

Operating voltage
Angle of coverage
Mounting Height
Detection Range
Time setting
Protection class
Opr. temperature
The amount of light emitted
Emergency lighting
Emergency lighting duration
Battery
Power consumption (Active/Stand-by)
Detection range is +20°C ambient temprature determined at.
SETTING
(e) Daylight setting
The sensor's response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob clockwise device will operate at dark.
Control dial set
= daylight operation approx. 2000 lux.
Control dial set
= night-time operation approx. 2 lux.
(f) Time setting
Light ON time can be adjusted continuously from "5 sec. ± 1 sec. / 5 min. ± 10 sec." If you turn
the knob anticlockwise device will operate at minimum time. (10 seconds)
Control dial set to - = Shortest time (5 sec. ± 1 sec.)
Control dial set to + = Longest time (5 min. ± 10 sec.)
NOTE: Device will automatically make its own offset by checking environment for approximately
5 minutes after the first installation. After this period device will operate normally. If you think
the device does not operate normal in first installation, please wait for 5 minutes and start to
test again. Be sure that there is no motion by this period.
www.na-de.com.tr • info@na-de.com.tr
‹stanbul Deri Organize Sanayi Bölgesi Tufle Sok. No:8
M1-8 Özel Parsel 34953 Tuzla / ‹STANBUL - TÜRK‹YE
10551
10651
~230-240Vac / 50-60 Hz
360°
2.8 m.
9 m.
5 sec. ± 1 sec. / 5 min. ± 10 sec.
IP20
Class I
-20°C ~ +40°C
WW (3000K): 529 lm / CW (6500K): 575 lm
-
40 lm
-
2 hours
-
3x1.2V 1000mAh ni-mh AAA
8.5W / 1W
9W / 1.8W
As shown in figure, firstly open the string by turning
counter clockwise and take off the glass. Mount the
ceiling from places which shown in figure (c) and figure
(d). And first will connect ground connection, than
connect connector as shown in system components
part. Then lay the glass its place and fasten up the
glass by constricting the string.
DETECTING RANGE
4.5 m.
SYSTEM COMPONENTS
(a)
(b)
(c)
Neutral
Phase
Earth
(a) Clamping washer (b) Glass Cover
(e) Daylight setting nobe (f) Time setting nobe

TROUBLESHOOTING

MALFUNCTION
CAUSE
• Led's are off.
• Daylight adjustment set to
night-time mode during daytime
operate
• Power switch off or no electricity
• Fuse faulty
• There is no
• Fuse switch off or fuse faulty
electricity on the
device
• Connection faulty.
• Continuously
• Continuously movement in
leds is on
detection zone
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
trees & bushes or open windows in
detection zone.
• Change perception
• Sudden temperature changes due
area in device
to weather(wind, rain, snow) or the
air expelled from fans.
• Different ambient temperatures.
DETECTION AREA :
Detection area of motion sensors depends on the angle between PIR detector and moving direction,
temperature , mounting style and mounting place. Temperature is very important for operation for
motion sensor like all electronic devices. Environment temperature will cause to decrease of detection
range. Detection range given is determined at +20°C. If the weather is hot, it will decrease.
Walking targential to the sensor
4.5 m
The maximum detection range can be realized when walking tangential to the sensor (figure1) When
walking directly to the sensor detection range will be low. Because you will not be able to cut vertical
areas. Detection range of 10551 and 10651 is 9 meters as diameter, 4,5 meters as radius.
GUARANTY
We will remedy defects caused by material flaws or manufacturing faults. The warranty will be met
by repair or replacement at our own discretion. The warranty shall not cover damage to wear parts,
damage or defects caused by improper treatment or maintenance. Further consequential damage to
other object is excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well packed
complete with a brief description of the fault, a receipt or invoice ( date of purchase and dealer's
stamp) to the appropriate Service Center.
360°
4.5 m.
9 m.
(10651)
(10551)
(e)
(c)
(f)
(d)
(d)
L
N
L
Neutral
Phase
Earth
(c) Ceiling mount (d) Ceiling mount screw
SOLUTION
• Control daylight setting and
re-adjust
• Check the electricity and power
on.
• Change the fuse.
• Check the fuse if necessary use
a new fuse.
• Check the connection cables.
• Check the detection zone.
• Avert it is being detection.
• Change detection zone, change
site of installation.
• Change site of installation or keep
the reasons away.
• Change site of installation.
Figure 1
Walking directly to the sensor
2.5 m
Batteries are
out of warranty