3.3.2
Tank unit protection anode
The tank unit comes with a protection mag-
nesium anode (fig. 9). This non-rust anode in
normal operating conditions has life span of
5 years. It is, however, advisable to check
the erosion annually and replace it if worn.
To disassemble the tank unit flange (1),
remove the cover (5) and unscrew the two
nuts that fix the upper cover (4). Then lift
the upper cover (4) which is simply inserted
with pressure.
KEY
1
Tank unit flange
2
Gasket
3
Magnesium anode ø 33x185
4
Cover
5
Protection
3.3.3
Disassembly of the casing
To disassemble the casing of the boiler, pro-
ceed as follows (fig. 10):
– remove the cover (12) fixed with pin clut-
ches;
– remove the panel (8) which are fixed to
the sides by pin clutches;
– remove the control panel (9) whose sides
are fixed by four self-tapping screws;
– remove the back panels (6) and (7)
which are fixed to the sides by ten self-
tapping screws;
– disassemble the left side (3) unscrewing
the screws fixing it to the upper bracket
(5), and remove the screws that fix it to
the lower bracket (1);
– disassemble the right side (4) following
the same operations.
ESTELLE
5
1
2
3
4
3.3.4

Fault finding

Herefater we outline a number of potential
problems that may occur on the appliance
and the relevant list of actions required. A
working fault, in most cases, provocates
the "lock out" signal onto the control panel
Fig. 9
of the control box.
When this light turns on, the burner can
operate again only after the reset button
has been pressed; if this has been done
and a regular ignition occurs, it means the
failure can be defined momentary and not
dangerous. On the contrary, if the "lock out"
stays, the cause of the fault, as well as the
relevant action must be made according to
the following chart:
The burner does not ignite
– Check the electric connections.
– Check the regular fuel flow, the clean-
ness of the filters, of the nozzle and air
vent from the tube.
– Check the regular spark ignition and the
proper function of the burner.
The burner ignites regularly but the flame
goes out immediately
– Check the flame detection, the air cali-
6
7
2
11
9
3
12
4
5
9
RONDO'
1
1
ESTELLE
1
bration and the function of the appliance.
Difficulty in regulating the burner and/or
lack of yield
– Check: the regular flow of fuel, the clean-
ness of the boiler, the non obstruction of
the smoke duct, the real input supplied
by the burner and its cleanness (dust).
The boiler gets dirty easily
– Check the burner regulator (smoke
analysis), the fuel quantity, the flue
obstruction and the cleanness of the air
duct of the burner (dust).
The boiler does not heat up
– Control the cleanness of the shell, the
matching, the adjustment, the burner
performances, the pre-adjusted temper-
ature, the correct function and position
of the regulation stat.
– Make sure that the boiler is sufficiently
powerful for the appliance.
Smell of unburnt products
– Control the cleanness of the boiler shell
and the flue, the airtightness of the boiler
and of the flue ducts (door, combustion
chamber, smoke ducts, flue, washers).