Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5
Mounting
Check the scope of delivery.

5.1 Wall attachment

5.1.1 The fixing height for the attachment varies depending on the different ladder
lenghts.
The attachment must be mounted so that it is
easily accessible from the user´s standing position.
5.1.2 If the ladder shall be placed permanently in the shaft, the attachment must be
fixed in corresponding height and position, so that it does not extend into the moving
parts of the lift.
5.1.3 Mark the two drilling holes at the wall.
5.1.4 Drill the holes with a 14" drill.
If you are mounting the attachment with triangular lock, the
sheet including the triangular lock must be placed underneath the
attachment, so that the drilling holes are on top of each other.
5.1.5 Fix the attachment to the wall.
Unevenness of the wall up to max. 1cm can be compensated with the provided big
washers.
5.1.6 Wall attachment with monitoring switch
Install the switch for monitoring the attachment professionally
in series to the emergency break switch in the safety circuit of
the lift control system. The rated current of the switch is 3A at
AC15 250V/50Hz and 3A at DC13 24V.
5.1.7 Wall attachment with U-lock or triangular lock
Hook the ladder into the attachment to make sure that no
unauthorized persons can use it.
Push the bracket with its longer side into the designated slot
on the left side in the bottom of the attachment.
Secure the ladder with the U-lock or the triangular lock.
© W
W 08/2016 Version 7
&
ID32907
11

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für W&W 78300

Inhaltsverzeichnis