Herunterladen Inhalt Inhalt Diese Seite drucken

Whale GW0500 Bedienungsanleitung Seite 3

Shower waste system
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
4. In sailboat operations, ensure the sump box is located close to the centre line and parallel with the bow-to-stern line.
5. Before installation, ensure there is enough overhead clearance to access the box for maintenance, ensure the best
angles for the hose (to prevent kinking) and ensure the lid tab is accessible.
Mounting Instructions
1. To open lid, release the tab on the box and lift upwards. To replace, ensure the tab is fully pressed down to ensure a
watertight seal.
Pilot Holes
2. Decide which opening size is needed and saw off the end - leaving all other unused inlet ports intact. File around
the outside and inside of the fitting to remove rough edges. (Figure 1)
NOTE Choose the port size as large as possible for optimum performance.
3. Place the sump box in final position. Mark narrow end of each keyhole screw slot locations, remove box and
carefully drill 6 x 3mm (⅛") pilot holes. (Figure 1)
NOTE Do not drill through hull, ensure that the product is mounted to additional board or bulkhead.
4. Replace box and fasten with six #8 stainless steel fasteners.
5. Connect 19mm (¾") or 25mm (1") I.D. hose from outlet fitting to the thru-hull connector. Secure each connection with
hose clamp.
NOTE Ensure tight connections, but do not over-tighten screws / hose clips.
NOTE - This pump must not be mounted below the water line unless the system has a vented loop or the thru-hull
connector is located above the maximum heeled water line.
6. Connect inlet hose from drains to the inlet fittings. Secure each connection with a hose clamp.
Plumbing
IMPORTANT: To prevent airlock, hose must rise continually
upward to the thru-hull connector with no dips or sharp bends
(Figure 2).
Hose support clips must be used to secure the pipework.
• Orientate the tank outlet for a direct path to the hull
connector ensuring an unobstructed hose path.
• Secure all connections with hose clamps.
• If no thru-hull connector exists, install at 305mm (12")
minimum height above water line. Apply marine sealant
around thru-hull flanges on interior and exterior of the hull.
Electrical Wiring
NOTE Switch off the power prior to making connections. Suggested wiring information is given as a guide only. For full
information, refer to the USCG, ABYC and ISO regulations for marine applications and wiring gauges, connectors and
fuse protection.
Ensure all wire connections are at the highest level above water. Waterproof all connections with suitable materials.
Warning - Do not cut or shorten wires as this will invalidate the warranty.
WARNING: POLARITY SENSITIVE Reversed wiring will cause switch and pump failure.
WARNING: Fire hazard. Wiring must comply with applicable electrical standards and include a properly rated fuse or
circuit breaker. Improper wiring can cause a fire resulting in injury or death.
Inlet - 19mm (¾") - 25mm (1")
Inlet - 28mm (1 ⅛") - 38mm (1 ½")
Outlet 19mm (¾") - 25mm (1")
To overboard
or grey water
tanks
305mm
above
Water line
Outside Boat
3
Pilot Holes
Vented Loop
Shower
Sink
Whale® Shower
Waste System
Figure 2 - Plumbing Schematic

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Gw0950Gw0954Gw0500bGw0950bGw0954b

Inhaltsverzeichnis