Motor Feedback Wiring

The Exp 24 Controller provides interface circuits for a resolver and a thermistor used for
motor position feedback and temperature monitoring. These are low voltage analog signals;
therefore a quality shielded cable must used. The cable should have 4 twisted pairs with
individual foil shields with drain wires as well as an overall braided shield. The drain wire for
the individual pair shields should be connected only on the EXP 24 end, no connection on
Actuator end, while the overall braided shield should be connected to the housings on both
ends, ideally through the cable gland. The terminals will accept wires ranging from 24 AWG
to 12 AWG (0.08 – 2.5 mm
EXP- 24 Control
Cos Shield
Cos Low
Cos High
Sin Shield
Sin Low
Sin High
Ref Shield
Ref Low
Ref High
ACT Temp Shied
ACT Temp
ACT Temp
Function
Cos Shield
Cos Low
Cos High
Sin Shield
Sin Low
Sin High
2
).
20 ft.
max
Braided Shield
Motor Feedback Cable
Terminal
J16
Ref Shield
J18
Ref Low
J17
Ref High
J13
ACT Temp Shied
J15
ACT Temp
J14
ACT Temp
Curtiss-Wright | EXP-24
EL100 Actuator
Cos Low
Cos High
Sin Low
Sin High
Ref Low
Ref High
ACT Temp
ACT Temp
Function
Terminal
J12
J11
J10
J21
J19
J20
Rev. P
PN47676